5592 lines
230 KiB
Plaintext
5592 lines
230 KiB
Plaintext
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 16 hours, 9 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 30 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 30 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 33 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
|
||
*Mar 1 00:00:05.142: Read env variable - LICENSE_BOOT_LEVEL =
|
||
*Mar 1 00:00:05.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
|
||
*Mar 1 00:00:58.040: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:05.322: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
||
*Mar 1 00:01:06.219: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.219: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.811: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.459: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.810: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.984: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
|
||
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
|
||
###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 26 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset administratively down down
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#
|
||
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by consoleend
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================PASSWORD=============================================================
|
||
spawn telnet 172.16.20.17 23
|
||
Trying 172.16.20.17...
|
||
Connected to 172.16.20.17.
|
||
Escape character is '^]'.
|
||
|
||
AU-dev#clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#
|
||
AU-dev#p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
|
||
|
||
User Access Verification
|
||
|
||
Password:
|
||
|
||
|
||
=============================================================PASSWORD=============================================================
|
||
spawn telnet 172.16.20.17 23
|
||
Trying 172.16.20.17...
|
||
Connected to 172.16.20.17.
|
||
Escape character is '^]'.
|
||
|
||
AU-dev#clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#
|
||
AU-dev#p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
|
||
|
||
User Access Verification
|
||
|
||
Password:
|
||
% Password: timeout expired!
|
||
% Bad passwords
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Router con0 is now available
|
||
|
||
|
||
|
||
|
||
|
||
Press RETURN to get started.
|
||
|
||
|
||
|
||
|
||
|
||
=============================================================PASSWORD=============================================================
|
||
spawn telnet 172.16.20.17 23
|
||
Trying 172.16.20.17...
|
||
Connected to 172.16.20.17.
|
||
Escape character is '^]'.
|
||
|
||
AU-dev#clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#
|
||
AU-dev#p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
|
||
|
||
User Access Verification
|
||
|
||
Password:
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 18 hours, 27 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 35 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 35 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 38 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
|
||
*Mar 1 00:00:05.142: Read env variable - LICENSE_BOOT_LEVEL =
|
||
*Mar 1 00:00:05.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
|
||
*Mar 1 00:00:58.040: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:05.322: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
||
*Mar 1 00:01:06.219: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.219: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.811: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.459: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.810: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.984: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
|
||
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 16:10:03.776: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:16.342: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:17.223: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 16:10:28.178: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 29 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset administratively down down
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#interface Te1/1/1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 1 minute
|
||
System returned to ROM by power-on
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: power-on
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:01:08 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 18 Celsius, Normal
|
||
Intake Left temperature: 22 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 24 Celsius, Normal
|
||
Exhaust Right temperature: 25 Celsius, Normal
|
||
CPU temperature: 47 Celsius, Normal
|
||
Power Supply Unit temperature: 26 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 49.6 W
|
||
Total System Power consumption is: 49.6 W
|
||
|
||
Environmental information last updated 00:00:17 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 20 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 20 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 23 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.775: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.951: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.111: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 02:12:09.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 02:12:16.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 02:12:27.331: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 02:12:27.331: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:12:27.331: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:12:27.331: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:12:28.531: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:12:28.531: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:12:28.531: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:12:29.283: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 20 02:12:37.675: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 02:12:37.675: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 02:12:37.675: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 02:12:37.675: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 02:12:38.711: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 02:12:40.867: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 02:12:40.907: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/1 unassigned YES unset administratively down down
|
||
GigabitEthernet0/2 unassigned YES unset administratively down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 7 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: power-on
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:07:08 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 18 Celsius, Normal
|
||
Intake Left temperature: 22 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 24 Celsius, Normal
|
||
Exhaust Right temperature: 25 Celsius, Normal
|
||
CPU temperature: 47 Celsius, Normal
|
||
Power Supply Unit temperature: 26 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 49.3 W
|
||
Total System Power consumption is: 49.3 W
|
||
|
||
Environmental information last updated 00:00:25 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 20 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 20 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 23 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.759: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.935: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 02:19:36.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 02:19:43.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 02:19:54.327: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 02:19:54.327: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:19:54.327: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:19:54.327: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:19:55.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:19:55.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:19:55.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:19:56.283: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 20 02:25:57.079: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 02:25:57.079: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 02:25:57.079: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 02:25:57.079: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 02:25:58.095: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 02:26:00.351: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 02:26:00.387: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/1 unassigned YES unset administratively down down
|
||
GigabitEthernet0/2 unassigned YES unset administratively down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================Wait=============================================================
|
||
Device has been broken waiting for testing
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 1 minute
|
||
System returned to ROM by reload at 02:38:21 UTC Thu Jul 20 2023
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2102
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:01:12 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 18 Celsius, Normal
|
||
Intake Left temperature: 22 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 24 Celsius, Normal
|
||
Exhaust Right temperature: 25 Celsius, Normal
|
||
CPU temperature: 47 Celsius, Normal
|
||
Power Supply Unit temperature: 26 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 49.5 W
|
||
Total System Power consumption is: 49.5 W
|
||
|
||
Environmental information last updated 00:00:26 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 21 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 21 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 24 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.763: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.943: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.103: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 02:40:42.643: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 02:40:49.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 02:41:00.399: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 02:41:00.399: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:41:00.399: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:41:00.399: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:41:01.599: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 02:41:01.599: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 02:41:01.599: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 02:41:02.827: %SYS-5-CONFIG_I: Configured from memory by console
|
||
*Jul 20 02:41:04.815: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 02:41:04.815: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 02:41:04.815: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 02:41:04.815: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 02:41:05.839: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 02:41:07.935: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 02:41:07.975: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|
||
*Jul 20 02:41:08.591: %SYS-6-BOOTTIME: Time taken to reboot after reload = 164 seconds###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
|
||
GigabitEthernet0/0 unassigned YES NVRAM administratively down down
|
||
GigabitEthernet0/1 unassigned YES NVRAM administratively down down
|
||
GigabitEthernet0/2 unassigned YES NVRAM administratively down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 19 hours, 41 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 40 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 40 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 43 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
|
||
*Mar 1 00:00:05.142: Read env variable - LICENSE_BOOT_LEVEL =
|
||
*Mar 1 00:00:05.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
|
||
*Mar 1 00:00:58.040: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:05.322: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
||
*Mar 1 00:01:06.219: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.219: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.811: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.459: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.810: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.984: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
|
||
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:03.776: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:16.342: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:17.223: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:28.178: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:26.875: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:37.948: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:39.432: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:49.792: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:51.353: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 30 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset administratively down down
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/1
|
||
Switch(config-if)#
|
||
*Mar 1 19:42:11.215: %SYS-5-CONFIG_I: Configured from console by consoleno shut
|
||
Switch(config-if)#end
|
||
Switch#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================loadingIOS=============================================================
|
||
clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#connect p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
rommon 1 > show info
|
||
|
||
monitor: command "show" not found
|
||
rommon 2 > set
|
||
PS1=rommon ! >
|
||
RTC_STAT=0
|
||
TFTP_RETRY_COUNT=20
|
||
WARM_REBOOT=FALSE
|
||
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
|
||
DEFAULT_GATEWAY=172.16.5.2
|
||
IP_ADDRESS=172.16.19.108
|
||
IP_SUBNET_MASK=255.255.0.0
|
||
TFTP_SERVER=192.168.5.7
|
||
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
?=0
|
||
RELOAD_TYPE=1
|
||
BSI=0
|
||
RANDOM_NUM=739966941
|
||
RET_2_RTS=03:09:10 UTC Thu Jul 20 2023
|
||
RET_2_RCALTS=1689822551
|
||
rommon 3 > showmon
|
||
Last Reset Reason: System Reset
|
||
|
||
ReadOnly ROMMON version is:
|
||
|
||
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
|
||
Copyright (c) 2011 by cisco Systems, Inc.
|
||
|
||
|
||
|
||
No upgrade ROMMON version present
|
||
ReadOnly ROMMON currently running
|
||
ReadOnly ROMMON is selected for next boot
|
||
rommon 4 > confreg
|
||
|
||
|
||
Configuration Summary
|
||
(Virtual Configuration Register: 0x2142)
|
||
enabled are:
|
||
load rom after netboot fails
|
||
ignore system config info
|
||
console baud: 9600
|
||
boot: image specified by the boot system commands
|
||
or default to: cisco2-CISCO2911/K9
|
||
|
||
do you wish to change the configuration? y/n [n]: n
|
||
|
||
|
||
rommon 5 >
|
||
rommon 5 >
|
||
rommon 5 > confreg 0x2142
|
||
|
||
|
||
rommon 6 > reset
|
||
|
||
|
||
|
||
|
||
=============================================================ERROR=============================================================
|
||
Load IOS failed+
|
||
=======================================*****Load IOS failed******
|
||
clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#connect p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
rommon 1 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 2 >
|
||
rommon 2 > set
|
||
PS1=rommon ! >
|
||
RTC_STAT=0
|
||
TFTP_RETRY_COUNT=20
|
||
WARM_REBOOT=FALSE
|
||
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
|
||
DEFAULT_GATEWAY=172.16.5.2
|
||
IP_ADDRESS=172.16.19.108
|
||
IP_SUBNET_MASK=255.255.0.0
|
||
TFTP_SERVER=192.168.5.7
|
||
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
?=0
|
||
RELOAD_TYPE=1
|
||
BSI=0
|
||
RANDOM_NUM=739966941
|
||
RET_2_RTS=03:09:10 UTC Thu Jul 20 2023
|
||
RET_2_RCALTS=1689822551
|
||
rommon 3 >
|
||
rommon 3 > showmon
|
||
Last Reset Reason: System Reset
|
||
|
||
ReadOnly ROMMON version is:
|
||
|
||
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
|
||
Copyright (c) 2011 by cisco Systems, Inc.
|
||
|
||
|
||
|
||
No upgrade ROMMON version present
|
||
ReadOnly ROMMON currently running
|
||
ReadOnly ROMMON is selected for next boot
|
||
rommon 4 > show info
|
||
|
||
monitor: command "show" not found
|
||
rommon 5 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 6 > format flash:
|
||
|
||
monitor: command "format" not found
|
||
rommon 7 > y
|
||
|
||
monitor: command "y" not found
|
||
rommon 8 > DEFAULT_GATEWAY=172.16.5.2
|
||
rommon 9 > IP_ADDRESS=172.16.19.105
|
||
rommon 10 > IP_SUBNET_MASK=255.255.0.0
|
||
rommon 11 > TFTP_SERVER=192.168.5.7
|
||
rommon 12 > TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
rommon 13 >
|
||
|
||
|
||
|
||
=============================================================ERROR=============================================================
|
||
Load IOS failed+
|
||
=======================================*****Load IOS failed******
|
||
clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#connect p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
rommon 14 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 15 >
|
||
rommon 15 > set
|
||
PS1=rommon ! >
|
||
RTC_STAT=0
|
||
TFTP_RETRY_COUNT=20
|
||
WARM_REBOOT=FALSE
|
||
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
|
||
RELOAD_TYPE=1
|
||
?=0
|
||
DEFAULT_GATEWAY=172.16.5.2
|
||
IP_ADDRESS=172.16.19.105
|
||
IP_SUBNET_MASK=255.255.0.0
|
||
TFTP_SERVER=192.168.5.7
|
||
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
BSI=0
|
||
RANDOM_NUM=739966941
|
||
RET_2_RTS=03:09:10 UTC Thu Jul 20 2023
|
||
RET_2_RCALTS=1689822551
|
||
rommon 16 >
|
||
rommon 16 > showmon
|
||
Last Reset Reason: System Reset
|
||
|
||
ReadOnly ROMMON version is:
|
||
|
||
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
|
||
Copyright (c) 2011 by cisco Systems, Inc.
|
||
|
||
|
||
|
||
No upgrade ROMMON version present
|
||
ReadOnly ROMMON currently running
|
||
ReadOnly ROMMON is selected for next boot
|
||
rommon 17 > show info
|
||
|
||
monitor: command "show" not found
|
||
rommon 18 > confreg
|
||
|
||
|
||
Configuration Summary
|
||
(Virtual Configuration Register: 0x2142)
|
||
enabled are:
|
||
load rom after netboot fails
|
||
ignore system config info
|
||
console baud: 9600
|
||
boot: image specified by the boot system commands
|
||
or default to: cisco2-CISCO2911/K9
|
||
|
||
do you wish to change the configuration? y/n [n]: n
|
||
|
||
|
||
rommon 19 >
|
||
rommon 19 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 20 > format flash:
|
||
|
||
monitor: command "format" not found
|
||
rommon 21 > y
|
||
|
||
monitor: command "y" not found
|
||
rommon 22 > DEFAULT_GATEWAY=172.16.5.2
|
||
rommon 23 > IP_ADDRESS=172.16.19.105
|
||
rommon 24 > IP_SUBNET_MASK=255.255.0.0
|
||
rommon 25 > TFTP_SERVER=192.168.5.7
|
||
rommon 26 > TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
rommon 27 > tftpdnld
|
||
|
||
IP_ADDRESS: 172.16.19.105
|
||
IP_SUBNET_MASK: 255.255.0.0
|
||
DEFAULT_GATEWAY: 172.16.5.2
|
||
TFTP_SERVER: 192.168.5.7
|
||
TFTP_FILE: i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
TFTP_MACADDR: e0:2f:6d:31:80:80
|
||
TFTP_DESTINATION: flash0:
|
||
GE_PORT: Ge0/0
|
||
TFTP_MEDIA_TYPE: Copper
|
||
TFTP_VERBOSE: Progress
|
||
TFTP_RETRY_COUNT: 20
|
||
TFTP_TIMEOUT: 7200
|
||
TFTP_CHECKSUM: Yes
|
||
GE_SPEED_MODE: Auto Detect
|
||
|
||
Invoke this command for disaster recovery only.
|
||
WARNING: all existing data in all partitions on flash will be lost!
|
||
Do you wish to continue? y/n: [n]: y
|
||
|
||
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 10 minutes
|
||
System returned to ROM by reload at 03:09:10 UTC Thu Jul 20 2023
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:10:05 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 19 Celsius, Normal
|
||
Intake Left temperature: 21 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
|
||
Exhaust Right temperature: 26 Celsius, Normal
|
||
CPU temperature: 48 Celsius, Normal
|
||
Power Supply Unit temperature: 27 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 50.7 W
|
||
Total System Power consumption is: 50.7 W
|
||
|
||
Environmental information last updated 00:00:27 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 29 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 29 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 32 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.767: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.943: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.103: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 06:18:53.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 06:19:00.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 06:19:11.379: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:19:13.323: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 06:23:37.767: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 06:23:37.767: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 06:23:40.115: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 06:23:40.151: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|
||
*Jul 20 06:23:40.767: %SYS-6-BOOTTIME: Time taken to reboot after reload = 11670 seconds
|
||
*Jul 20 06:27:32.591: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 20 06:27:34.359: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 06:27:34.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:27:34.447: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:27:38.387: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:27:39.387: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:27:58.011: %SYS-5-CONFIG_I: Configured from console by console###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset up up
|
||
GigabitEthernet0/1 unassigned YES unset down down
|
||
GigabitEthernet0/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================PASSWORD=============================================================
|
||
spawn telnet 172.16.20.17 23
|
||
Trying 172.16.20.17...
|
||
Connected to 172.16.20.17.
|
||
Escape character is '^]'.
|
||
|
||
AU-dev#clear line 20
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#
|
||
AU-dev#p3
|
||
Trying p3 (1.1.1.1, 2020)... Open
|
||
|
||
|
||
|
||
Rom image verified correctly
|
||
|
||
|
||
|
||
Cisco Systems ROMMON, Version 1.1.12, RELEASE SOFTWARE
|
||
Copyright (c) 1994-2017 by Cisco Systems, Inc.
|
||
Compiled Wed 06/28/2017 14:36:11.63 by wchen64
|
||
|
||
|
||
|
||
Current image running: Boot ROM1
|
||
|
||
Last reset cause: PowerOn
|
||
|
||
DIMM Slot 0 : Present
|
||
|
||
DIMM Slot 1 : Present
|
||
|
||
|
||
Platform ASA5516 with 8192 Mbytes of main memory
|
||
|
||
MAC Address: ec:bd:1d:5f:a6:31
|
||
|
||
|
||
|
||
Use BREAK or ESC to interrupt boot.
|
||
|
||
Use SPACE to begin boot immediately.
|
||
|
||
Boot in 10 seconds. Boot in 9 seconds. Boot in 8 seconds. Boot in 7 seconds. Boot in 6 seconds. Boot in 5 seconds. Boot in 4 seconds.Æüÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿþÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿþÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿ/gû)ô9)) 'Processor memory 3754858905
|
||
|
||
Compiled on Wed 12-Aug-15 12:18 PDT by builders
|
||
|
||
Total NICs found: 13
|
||
i354 rev03 Gigabit Ethernet @ irq255 dev 20 index 08 MAC: ecbd.1d5f.a631
|
||
ivshmem rev03 Backplane Data Interface @ index 09 MAC: 0000.0001.0002
|
||
en_vtun rev00 Backplane Control Interface @ index 10 MAC: 0000.0001.0001
|
||
en_vtun rev00 Backplane Int-Mgmt Interface @ index 11 MAC: 0000.0001.0003
|
||
en_vtun rev00 Backplane Ext-Mgmt Interface @ index 12 MAC: 0000.0000.0000
|
||
Verify the activation-key, it might take a while...
|
||
Running Permanent Activation Key: 0x803fd871 0x648697a2 0x88b2913c 0xbf282ce4 0x8233308c
|
||
The Running Activation Key feature: 500 AnyConnect Premium sessions exceed the limit on the platform, reduced to 300 AnyConnect Premium sessions.
|
||
|
||
Licensed features for this platform:
|
||
Maximum Physical Interfaces : Unlimited perpetual
|
||
Maximum VLANs : 150 perpetual
|
||
Inside Hosts : Unlimited perpetual
|
||
Failover : Active/Active perpetual
|
||
Encryption-DES : Enabled perpetual
|
||
Encryption-3DES-AES : Enabled perpetual
|
||
Security Contexts : 2 perpetual
|
||
GTP/GPRS : Disabled perpetual
|
||
AnyConnect Premium Peers : 300 perpetual
|
||
AnyConnect Essentials : Disabled perpetual
|
||
Other VPN Peers : 300 perpetual
|
||
Total VPN Peers : 300 perpetual
|
||
Shared License : Disabled perpetual
|
||
AnyConnect for Mobile : Enabled perpetual
|
||
AnyConnect for Cisco VPN Phone : Enabled perpetual
|
||
Advanced Endpoint Assessment : Enabled perpetual
|
||
Total UC Proxy Sessions : 1000 perpetual
|
||
Botnet Traffic Filter : Disabled perpetual
|
||
Cluster : Disabled perpetual
|
||
VPN Load Balancing : Enabled perpetual
|
||
|
||
|
||
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 13 minutes
|
||
System returned to ROM by reload at 03:09:10 UTC Thu Jul 20 2023
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:13:07 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 19 Celsius, Normal
|
||
Intake Left temperature: 21 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
|
||
Exhaust Right temperature: 26 Celsius, Normal
|
||
CPU temperature: 48 Celsius, Normal
|
||
Power Supply Unit temperature: 27 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 51.0 W
|
||
Total System Power consumption is: 51.0 W
|
||
|
||
Environmental information last updated 00:00:29 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 30 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 30 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 33 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.767: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.943: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.103: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 06:18:53.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 06:19:00.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 06:19:11.379: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:19:11.379: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:19:12.567: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:19:13.323: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 06:23:36.727: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 06:23:37.767: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 06:23:37.767: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 06:23:40.115: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 06:23:40.151: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|
||
*Jul 20 06:23:40.767: %SYS-6-BOOTTIME: Time taken to reboot after reload = 11670 seconds
|
||
*Jul 20 06:27:32.591: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 20 06:27:34.359: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 06:27:34.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:27:34.447: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:27:38.387: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:27:39.387: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:27:58.011: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 20 06:29:17.391: %SYS-5-CONFIG_I: Configured from console by console###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset up up
|
||
GigabitEthernet0/1 unassigned YES unset down down
|
||
GigabitEthernet0/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 23 hours, 21 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 49 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 49 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 52 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
ED: Switch 1 has been ADDED to the stack
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
||
*Mar 1 00:01:00.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:05.322: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
||
*Mar 1 00:01:06.219: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.219: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.811: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.459: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.810: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.984: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
|
||
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
|
||
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:03.776: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:16.342: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:17.223: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:28.178: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:26.875: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:37.948: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:39.432: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:49.792: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:51.353: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:00.108: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:11.215: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:12.767: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:13.689: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:24.636: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 22:52:20.141: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to up
|
||
*Mar 1 22:52:21.172: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to up
|
||
*Mar 1 22:52:27.682: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to down
|
||
*Mar 1 22:52:28.680: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 29 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset administratively down down
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#interface Te1/1/1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 23 hours, 32 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 54 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 54 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 57 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
N_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.219: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.811: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.459: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.459: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.810: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.984: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
|
||
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
|
||
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
|
||
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:03.776: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:16.342: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 16:10:17.223: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 16:10:28.178: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:26.875: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:37.948: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 18:27:39.432: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:49.792: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 18:27:51.353: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:00.108: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 19:42:11.215: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:12.767: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:13.689: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 19:42:24.636: %SYS-5-CONFIG_I: Configured from console by console
|
||
|
||
*Mar 1 22:52:20.141: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to up
|
||
*Mar 1 22:52:21.172: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to up
|
||
*Mar 1 22:52:27.682: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to down
|
||
*Mar 1 22:52:28.680: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down
|
||
*Mar 1 23:22:08.776: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 23:22:20.722: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 23:22:22.215: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 23:22:32.558: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 23:22:34.177: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 29 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset administratively down down
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#
|
||
*Mar 1 23:32:59.221: %SYS-5-CONFIG_I: Configured from console by consoleend
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#interface Te1/1/1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 10 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: power-on
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 00:10:37 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 20 Celsius, Normal
|
||
Intake Left temperature: 21 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
|
||
Exhaust Right temperature: 26 Celsius, Normal
|
||
CPU temperature: 49 Celsius, Normal
|
||
Power Supply Unit temperature: 27 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 49.0 W
|
||
Total System Power consumption is: 49.0 W
|
||
|
||
Environmental information last updated 00:00:25 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 21 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 21 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 24 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.767: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.943: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.103: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 20 06:42:38.643: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 20 06:42:45.063: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 20 06:42:56.335: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 20 06:42:56.335: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:42:56.335: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:42:56.335: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:42:57.523: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 20 06:42:57.523: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 20 06:42:57.523: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 20 06:42:58.279: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 20 06:52:27.167: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 20 06:52:27.167: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 20 06:52:27.167: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 20 06:52:27.167: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 20 06:52:28.219: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 20 06:52:28.219: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 20 06:52:30.367: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 20 06:52:30.407: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/1 unassigned YES unset administratively down down
|
||
GigabitEthernet0/2 unassigned YES unset administratively down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================loadingIOS=============================================================
|
||
clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#connect p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
rommon 1 > show info
|
||
|
||
monitor: command "show" not found
|
||
rommon 2 > set
|
||
PS1=rommon ! >
|
||
RTC_STAT=0
|
||
TFTP_RETRY_COUNT=20
|
||
WARM_REBOOT=FALSE
|
||
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
|
||
DEFAULT_GATEWAY=172.16.5.2
|
||
IP_ADDRESS=172.16.19.105
|
||
IP_SUBNET_MASK=255.255.0.0
|
||
TFTP_SERVER=192.168.5.7
|
||
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
?=0
|
||
RELOAD_TYPE=1
|
||
RANDOM_NUM=1295944857
|
||
BSI=0
|
||
RET_2_RTS=06:59:41 UTC Thu Jul 20 2023
|
||
RET_2_RCALTS=1689836381
|
||
rommon 3 > showmon
|
||
Last Reset Reason: System Reset
|
||
|
||
ReadOnly ROMMON version is:
|
||
|
||
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
|
||
Copyright (c) 2011 by cisco Systems, Inc.
|
||
|
||
|
||
|
||
No upgrade ROMMON version present
|
||
ReadOnly ROMMON currently running
|
||
ReadOnly ROMMON is selected for next boot
|
||
rommon 4 > confreg
|
||
|
||
|
||
Configuration Summary
|
||
(Virtual Configuration Register: 0x2142)
|
||
enabled are:
|
||
load rom after netboot fails
|
||
ignore system config info
|
||
console baud: 9600
|
||
boot: image specified by the boot system commands
|
||
or default to: cisco2-CISCO2911/K9
|
||
|
||
do you wish to change the configuration? y/n [n]: n
|
||
|
||
|
||
rommon 5 >
|
||
rommon 5 >
|
||
rommon 5 > confreg 0x2142
|
||
|
||
|
||
rommon 6 > reset
|
||
|
||
|
||
|
||
|
||
=============================================================Wait=============================================================
|
||
Device has been broken waiting for testing
|
||
|
||
|
||
=============================================================ERROR=============================================================
|
||
Load IOS failed+
|
||
=======================================*****Load IOS failed******
|
||
clear line 22
|
||
[confirm]
|
||
[OK]
|
||
AU-dev#connect p5
|
||
Trying p5 (1.1.1.1, 2022)... Open
|
||
|
||
rommon 1 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 2 >
|
||
rommon 2 > set
|
||
PS1=rommon ! >
|
||
RTC_STAT=0
|
||
TFTP_RETRY_COUNT=20
|
||
WARM_REBOOT=FALSE
|
||
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
|
||
DEFAULT_GATEWAY=172.16.5.2
|
||
IP_ADDRESS=172.16.19.105
|
||
IP_SUBNET_MASK=255.255.0.0
|
||
TFTP_SERVER=192.168.5.7
|
||
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
?=0
|
||
RELOAD_TYPE=1
|
||
RANDOM_NUM=1295944857
|
||
BSI=0
|
||
RET_2_RTS=06:59:41 UTC Thu Jul 20 2023
|
||
RET_2_RCALTS=1689836381
|
||
rommon 3 >
|
||
rommon 3 > showmon
|
||
Last Reset Reason: System Reset
|
||
|
||
ReadOnly ROMMON version is:
|
||
|
||
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
|
||
Copyright (c) 2011 by cisco Systems, Inc.
|
||
|
||
|
||
|
||
No upgrade ROMMON version present
|
||
ReadOnly ROMMON currently running
|
||
ReadOnly ROMMON is selected for next boot
|
||
rommon 4 > show info
|
||
|
||
monitor: command "show" not found
|
||
rommon 5 > confreg
|
||
|
||
|
||
Configuration Summary
|
||
(Virtual Configuration Register: 0x2142)
|
||
enabled are:
|
||
load rom after netboot fails
|
||
ignore system config info
|
||
console baud: 9600
|
||
boot: image specified by the boot system commands
|
||
or default to: cisco2-CISCO2911/K9
|
||
|
||
do you wish to change the configuration? y/n [n]: n
|
||
|
||
|
||
rommon 6 >
|
||
rommon 6 > flash_init
|
||
|
||
monitor: command "flash_init" not found
|
||
rommon 7 > format flash:
|
||
|
||
monitor: command "format" not found
|
||
rommon 8 > y
|
||
|
||
monitor: command "y" not found
|
||
rommon 9 > DEFAULT_GATEWAY=172.16.5.2
|
||
rommon 10 > IP_ADDRESS=172.16.19.105
|
||
rommon 11 > IP_SUBNET_MASK=255.255.0.0
|
||
rommon 12 > TFTP_SERVER=192.168.5.7
|
||
rommon 13 > TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
rommon 14 > tftpdnld
|
||
|
||
IP_ADDRESS: 172.16.19.105
|
||
IP_SUBNET_MASK: 255.255.0.0
|
||
DEFAULT_GATEWAY: 172.16.5.2
|
||
TFTP_SERVER: 192.168.5.7
|
||
TFTP_FILE: i/c2900-universalk9-mz.SPA.152-4.M4.bin
|
||
TFTP_MACADDR: e0:2f:6d:31:80:80
|
||
TFTP_DESTINATION: flash0:
|
||
GE_PORT: Ge0/0
|
||
TFTP_MEDIA_TYPE: Copper
|
||
TFTP_VERBOSE: Progress
|
||
TFTP_RETRY_COUNT: 20
|
||
TFTP_TIMEOUT: 7200
|
||
TFTP_CHECKSUM: Yes
|
||
GE_SPEED_MODE: Auto Detect
|
||
|
||
Invoke this command for disaster recovery only.
|
||
WARNING: all existing data in all partitions on flash will be lost!
|
||
Do you wish to continue? y/n: [n]: y
|
||
.....
|
||
Receiving i/c2900-universalk9-mz.SPA.152-4.M4.bin from 192.168.5.7 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
|
||
File reception completed.
|
||
IOS Image Load Test
|
||
___________________
|
||
Digitally Signed Release Software
|
||
|
||
Validating checksum.
|
||
Copying file i/c2900-universalk9-mz.SPA.152-4.M4.bin to flash0:.
|
||
program load complete, entry point: 0x80803000, size: 0x1b340
|
||
|
||
Format: All system sectors written. OK...
|
||
|
||
Format: Total sectors in formatted partition: 501728
|
||
Format: Total bytes in formatted partition: %llu
|
||
Format: Operation completed successfully.
|
||
program load complete, entry point: 0x80803000, size: 0x1b340
|
||
|
||
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
iscoasa###show inv
|
||
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
|
||
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
|
||
|
||
|
||
|