###show inv
|
|
NAME: "CISCO2911/K9 chassis", DESCR: "CISCO2911/K9 chassis"
|
|
PID: CISCO2911/K9 , VID: V05 , SN: FGL160410P4
|
|
|
|
NAME: "C2911 AC Power Supply", DESCR: "C2911 AC Power Supply"
|
|
PID: PWR-2911-AC , VID: V04 , SN: DCA1548R0GR
|
|
|
|
###show ver
|
|
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(3)T1, RELEASE SOFTWARE (fc2)
|
|
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2011 by Cisco Systems, Inc.
|
|
Compiled Sun 27-Mar-11 07:36 by prod_rel_team
|
|
|
|
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
|
|
|
Router uptime is 1 hour, 16 minutes
|
|
System returned to ROM by power-on
|
|
System image file is "flash0:c2900-universalk9-mz.SPA.151-3.T1.bin"
|
|
Last reload type: Normal Reload
|
|
|
|
|
|
This product contains cryptographic features and is subject to United
|
|
States and local country laws governing import, export, transfer and
|
|
use. Delivery of Cisco cryptographic products does not imply
|
|
third-party authority to import, export, distribute or use encryption.
|
|
Importers, exporters, distributors and users are responsible for
|
|
compliance with U.S. and local country laws. By using this product you
|
|
agree to comply with applicable laws and regulations. If you are unable
|
|
to comply with U.S. and local laws, return this product immediately.
|
|
|
|
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
|
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
|
|
|
If you require further assistance please contact us by sending email to
|
|
export@cisco.com.
|
|
|
|
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
|
Processor board ID FGL160410P4
|
|
3 Gigabit Ethernet interfaces
|
|
DRAM configuration is 64 bits wide with parity enabled.
|
|
255K bytes of non-volatile configuration memory.
|
|
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
|
|
|
|
|
License Info:
|
|
|
|
License UDI:
|
|
|
|
-------------------------------------------------
|
|
Device# PID SN
|
|
-------------------------------------------------
|
|
*0 CISCO2911/K9 FGL160410P4
|
|
|
|
|
|
|
|
|
|
Technology Package License Information for Module:'c2900'
|
|
|
|
----------------------------------------------------------------
|
|
Technology Technology-package Technology-package
|
|
Current Type Next reboot
|
|
-----------------------------------------------------------------
|
|
ipbase ipbasek9 Permanent ipbasek9
|
|
security None None None
|
|
uc None None None
|
|
data datak9 Permanent datak9
|
|
|
|
Configuration register is 0x2102
|
|
###show diag
|
|
Slot 0:
|
|
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
|
Port adapter is analyzed
|
|
Port adapter insertion time 01:16:42 ago
|
|
EEPROM contents at hardware discovery:
|
|
PCB Serial Number : FOC15520Q9W
|
|
Hardware Revision : 1.0
|
|
Part Number : 73-11833-08
|
|
Top Assy. Part Number : 800-30797-04
|
|
Board Revision : C0
|
|
Deviation Number : 0
|
|
Fab Version : 03
|
|
Product (FRU) Number : CISCO2911/K9
|
|
Version Identifier : V05
|
|
CLEI Code : CMMBR00ARC
|
|
Processor type : C1
|
|
Chassis Serial Number : FGL160410P4
|
|
Chassis MAC Address : f0f7.5532.71e0
|
|
MAC Address block size : 80
|
|
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
|
EEPROM format version 4
|
|
EEPROM contents (hex):
|
|
0x00: 04 FF C1 8B 46 4F 43 31 35 35 32 30 51 39 57 40
|
|
0x10: 06 18 41 01 00 82 49 2E 39 08 C0 46 03 20 00 78
|
|
0x20: 4D 04 42 43 30 88 00 00 00 00 02 03 CB 8C 43 49
|
|
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 35 20 D9
|
|
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 42 52 30 30 41 52
|
|
0x50: 43 09 C1 C2 8B 46 47 4C 31 36 30 34 31 30 50 34
|
|
0x60: C3 06 F0 F7 55 32 71 E0 43 00 50 C4 08 00 00 00
|
|
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
|
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
Internal Power Supply information
|
|
Top Assy. Part Number : 341-0235-06
|
|
Deviation Number : 0
|
|
PCB Serial Number : DCA1548R0GR
|
|
RMA Test History : 00
|
|
RMA Number : 0-0-0-0
|
|
RMA History : 00
|
|
Version Identifier : V04
|
|
Product (FRU) Number : PWR-2911-AC
|
|
CLEI Code : 0000000000
|
|
Board Revision : A0
|
|
EEPROM format version 4
|
|
EEPROM contents (hex):
|
|
|
|
0x00: 04 FF 40 05 E5 DF 45 01 55 00 EB 06 88 00 00 00
|
|
0x10: 00 C1 8B 44 43 41 31 35 34 38 52 30 47 52 03 00
|
|
0x20: 81 00 00 00 00 04 00 89 56 30 34 20 CB 8B 50 57
|
|
0x30: 52 2D 32 39 31 31 2D 41 43 C6 8A 30 30 30 30 30
|
|
0x40: 30 30 30 30 30 F3 00 59 41 00 BE 42 00 05 F8 00
|
|
0x50: 50 01 F3 15 97 02 F0 18 3B 03 E6 19 FB 04 E2 1B
|
|
0x60: 1C 05 D9 1C 53 06 D8 1D 4F 07 D6 1D B6 08 CE 1E
|
|
0x70: 40 09 C2 1E ED 0A B8 1F B1 0B B9 20 20 0D AF 20
|
|
0x80: 86 0F 9B 20 ED 11 91 21 3F 13 87 21 62 17 74 21
|
|
0x90: C0 1B 57 21 DB 1F 38 21 F3 23 25 21 FC 27 0A 21
|
|
0xA0: F3 42 41 30 FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
###show post
|
|
^
|
|
% Invalid input detected at '^' marker.
|
|
###show env all
|
|
SYSTEM POWER SUPPLY STATUS
|
|
==========================
|
|
Internal Power Supply Type: AC
|
|
Internal Power Supply 12V Output Status: Normal
|
|
|
|
External Redundant Power Supply is absent or powered off
|
|
|
|
SYSTEM FAN STATUS
|
|
=================
|
|
Fan 1 OK, Low speed setting
|
|
Fan 2 OK, Low speed setting
|
|
Fan 3 OK, Low speed setting
|
|
Fan 4 OK, Low speed setting
|
|
|
|
SYSTEM TEMPERATURE STATUS
|
|
=========================
|
|
Intake Left(Bezel) temperature: 18 Celsius, Normal
|
|
Intake Left temperature: 18 Celsius, Normal
|
|
Exhaust Right(Bezel) temperature: 23 Celsius, Normal
|
|
Exhaust Right temperature: 22 Celsius, Normal
|
|
CPU temperature: 49 Celsius, Normal
|
|
Power Supply Unit temperature: 21 Celsius, Normal
|
|
|
|
REAL TIME CLOCK BATTERY STATUS
|
|
==============================
|
|
Battery OK (checked at power up)
|
|
|
|
SYSTEM POWER
|
|
===============
|
|
Motherboard Components Power consumption = 43.6 W
|
|
Total System Power consumption is: 43.6 W
|
|
|
|
Environmental information last updated 00:00:21 ago
|
|
###show logging
|
|
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
|
|
|
No Active Message Discriminator.
|
|
|
|
|
|
|
|
No Inactive Message Discriminator.
|
|
|
|
|
|
Console logging: level debugging, 15 messages logged, xml disabled,
|
|
filtering disabled
|
|
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
|
filtering disabled
|
|
Buffer logging: level debugging, 15 messages logged, xml disabled,
|
|
filtering disabled
|
|
Exception Logging: size (4096 bytes)
|
|
Count and timestamp logging messages: disabled
|
|
Persistent logging: disabled
|
|
|
|
No active filter modules.
|
|
|
|
Trap logging: level informational, 18 message lines logged
|
|
|
|
Log Buffer (8192 bytes):
|
|
|
|
*Mar 1 00:00:12.219: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
|
*Mar 1 00:00:12.295: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
|
*May 17 00:38:40.611: %IFMGR-7-NO_IFINDEX_FILE: Unable to open nvram:/ifIndex-table No such file or directory
|
|
*May 17 00:38:51.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
|
|
|
*May 17 00:38:51.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
|
*May 17 00:38:51.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
|
*May 17 00:38:52.211: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
|
*May 17 00:38:52.211: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
|
*May 17 00:38:52.211: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
|
*May 17 01:54:01.015: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
|
*May 17 01:54:01.015: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
|
*May 17 01:54:01.015: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
|
*May 17 01:54:02.947: %IP-5-WEBINST_KILL: Terminating DNS process
|
|
*May 17 01:54:11.463: %SYS-5-RESTART: System restarted --
|
|
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(3)T1, RELEASE SOFTWARE (fc2)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2011 by Cisco Systems, Inc.
|
|
Compiled Sun 27-Mar-11 07:36 by prod_rel_team
|
|
*May 17 01:54:11.467: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|