CiscoTool_v1/netmiko_Api/public/filesTest/20230518-AUTO-Session.AUS-2...

220 lines
8.6 KiB
Plaintext

###show inv
NAME: "CISCO2911/K9 chassis", DESCR: "CISCO2911/K9 chassis"
PID: CISCO2911/K9 , VID: V02 , SN: FGL151412EC
NAME: "C2911 AC Power Supply", DESCR: "C2911 AC Power Supply"
PID: PWR-2911-AC , VID: V03 , SN: AZS151110F0
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.0(1)M4, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Thu 28-Oct-10 18:32 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M9, RELEASE SOFTWARE (fc1)
Router uptime is 43 minutes
System returned to ROM by power-on
System image file is "flash0:c2900-universalk9-mz.SPA.150-1.M4.bin"
Last reload type: Normal Reload
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL151412EC
3 Gigabit Ethernet interfaces
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL151412EC
Technology Package License Information for Module:'c2900'
----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
-----------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc None None None
data datak9 Permanent datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:43:07 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC15115UYG
Hardware Revision : 1.0
Part Number : 73-11833-06
Top Assy. Part Number : 800-30797-02
Board Revision : B0
Deviation Number : 113332
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V02
CLEI Code : CMMBR00ARA
Processor type : C1
Chassis Serial Number : FGL151412EC
Chassis MAC Address : 4055.39ab.b0e0
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 35 31 31 35 55 59 47 40
0x10: 06 18 41 01 00 82 49 2E 39 06 C0 46 03 20 00 78
0x20: 4D 02 42 42 30 88 00 01 BA B4 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 32 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 42 52 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 35 31 34 31 32 45 43
0x60: C3 06 40 55 39 AB B0 E0 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal power Supply information
Top Assy. Part Number : 341-0235-05
Deviation Number : 0
PCB Serial Number : AZS151110F0
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V03
Product (FRU) Number : PWR-2911-AC
CLEI Code :
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E5 DF 45 01 55 00 EB 05 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 35 31 31 31 30 46 30 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 33 20 CB 8B 50 57
0x30: 52 2D 32 39 31 31 2D 41 43 C6 8A 00 00 00 00 00
0x40: 00 00 00 00 00 F3 00 59 41 00 BE 42 00 05 F8 00
0x50: 50 01 F4 17 2B 02 EE 1A 7A 03 E8 1B 65 04 E2 1C
0x60: 47 05 DC 1C C9 06 D6 1D A3 07 D0 1E 54 08 CA 1E
0x70: E6 09 C4 1F 5C 0A BE 1F BF 0B B8 20 12 0D AC 20
0x80: 92 0F A0 20 F0 11 94 21 38 13 88 21 6B 17 70 21
0x90: AE 1B 58 21 D3 1F 40 21 E0 23 28 21 DE 27 10 22
0xA0: 56 42 41 30 FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC
Internal Power Supply 12V Output Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 23 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 25 Celsius, Normal
CPU temperature: 67 Celsius, Normal
Power Supply Unit temperature: 23 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 47.7 W
Total System Power consumption is: 47.7 W
Environmental information last updated 00:00:00 ago
###show logging
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited,
0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 11 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 11 messages logged, xml disabled,
filtering disabled
Logging Exception size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
ESM: 0 messages dropped
Trap logging: level informational, 15 message lines logged
Log Buffer (8192 bytes):
*Mar 1 00:00:09.503: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Mar 1 00:00:09.575: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*May 18 04:54:24.099: %SYS-5-CONFIG_I: Configured from memory by console
*May 18 04:54:26.571: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.0(1)M4, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Thu 28-Oct-10 18:32 by prod_rel_team
*May 18 04:54:26.575: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start