Switch####show inv
|
|
NAME: "c38xx Stack", DESCR: "c38xx Stack"
|
|
PID: WS-C3850-48P-S , VID: V06 , SN: FOC1937X1WD
|
|
|
|
NAME: "Switch 3", DESCR: "WS-C3850-48P-S"
|
|
PID: WS-C3850-48P-S , VID: V06 , SN: FOC1937X1WD
|
|
|
|
NAME: "Switch 3 - Power Supply A", DESCR: "Switch 3 - Power Supply A"
|
|
PID: PWR-C1-350WAC , VID: V01 , SN: LIT18200BHY
|
|
|
|
NAME: "Switch 3 FRU Uplink Module 1", DESCR: "4x1G Uplink Module"
|
|
PID: C3850-NM-4-1G , VID: V01 , SN: FOC193645WK
|
|
|
|
###show ver
|
|
Cisco IOS XE Software, Version 16.09.05
|
|
Cisco IOS Software [Fuji], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.9.5, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2020 by Cisco Systems, Inc.
|
|
Compiled Thu 30-Jan-20 18:17 by mcpre
|
|
|
|
|
|
Cisco IOS-XE software, Copyright (c) 2005-2020 by cisco Systems, Inc.
|
|
All rights reserved. Certain components of Cisco IOS-XE software are
|
|
licensed under the GNU General Public License ("GPL") Version 2.0. The
|
|
software code licensed under GPL Version 2.0 is free software that comes
|
|
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
|
|
GPL code under the terms of GPL Version 2.0. For more details, see the
|
|
documentation or "License Notice" file accompanying the IOS-XE software,
|
|
or the applicable URL provided on the flyer accompanying the IOS-XE
|
|
software.
|
|
|
|
|
|
ROM: IOS-XE ROMMON
|
|
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 4.68, RELEASE SOFTWARE (P)
|
|
|
|
Switch uptime is 1 minute
|
|
Uptime for this control processor is 4 minutes
|
|
System returned to ROM by Power Failure or Unknown
|
|
System image file is "flash:packages.conf"
|
|
Last reload reason: Power Failure or Unknown
|
|
|
|
|
|
|
|
This product contains cryptographic features and is subject to United
|
|
|
|
States and local country laws governing import, export, transfer and
|
|
use. Delivery of Cisco cryptographic products does not imply
|
|
third-party authority to import, export, distribute or use encryption.
|
|
Importers, exporters, distributors and users are responsible for
|
|
compliance with U.S. and local country laws. By using this product you
|
|
agree to comply with applicable laws and regulations. If you are unable
|
|
to comply with U.S. and local laws, return this product immediately.
|
|
|
|
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
|
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
|
|
|
If you require further assistance please contact us by sending email to
|
|
export@cisco.com.
|
|
|
|
|
|
Technology Package License Information:
|
|
|
|
------------------------------------------------------------------------------
|
|
Technology-package Technology-package
|
|
Current Type Next reboot
|
|
------------------------------------------------------------------------------
|
|
ipbasek9 Smart License ipbasek9
|
|
None Subscription Smart License None
|
|
|
|
|
|
Smart Licensing Status: UNREGISTERED/EVAL MODE
|
|
|
|
cisco WS-C3850-48P (MIPS) processor (revision X0) with 832395K/6147K bytes of memory.
|
|
Processor board ID FOC1937X1WD
|
|
1 Virtual Ethernet interface
|
|
52 Gigabit Ethernet interfaces
|
|
4 Ten Gigabit Ethernet interfaces
|
|
2048K bytes of non-volatile configuration memory.
|
|
4194304K bytes of physical memory.
|
|
250456K bytes of Crash Files at crashinfo:.
|
|
1609272K bytes of Flash at flash:.
|
|
0K bytes of WebUI ODM Files at webui:.
|
|
|
|
Base Ethernet MAC Address : 9c:57:ad:6e:8b:80
|
|
Motherboard Assembly Number : 73-15800-07
|
|
Motherboard Serial Number : FOC19378N63
|
|
Model Revision Number : X0
|
|
Motherboard Revision Number : B0
|
|
Model Number : WS-C3850-48P
|
|
System Serial Number : FOC1937X1WD
|
|
|
|
|
|
Switch Ports Model SW Version SW Image Mode
|
|
------ ----- ----- ---------- ---------- ----
|
|
* 3 56 WS-C3850-48P 16.9.5 CAT3K_CAA-UNIVERSALK9 INSTALL
|
|
|
|
|
|
Configuration register is 0x142 (will be 0x102 at next reload)
|
|
###show post
|
|
Stored system POST messages:
|
|
|
|
Switch 3
|
|
---------
|
|
|
|
POST: MBIST Tests : Begin
|
|
POST: MBIST Tests : End, Status Passed
|
|
|
|
POST: CRYPTO Tests : Begin
|
|
POST: CRYPTO Tests : End, Status Passed
|
|
|
|
POST: PHY Loopback: loopback Test : Begin
|
|
POST: PHY Loopback: loopback Test : End, Status Passed
|
|
|
|
POST: Inline Power Controller Tests : Begin
|
|
POST: Inline Power Controller Tests : End, Status Passed
|
|
|
|
POST: Thermal, Temperature Tests : Begin
|
|
POST: Thermal, Temperature Tests : End, Status Passed
|
|
|
|
POST: Thermal, Fan Tests : Begin
|
|
POST: Thermal, Fan Tests : End, Status Passed
|
|
|
|
POST: SIF Tests : Begin
|
|
POST: SIF Tests : End, Status Passed
|
|
|
|
###show logging
|
|
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
|
|
|
No Active Message Discriminator.
|
|
|
|
|
|
|
|
No Inactive Message Discriminator.
|
|
|
|
|
|
Console logging: level debugging, 56 messages logged, xml disabled,
|
|
filtering disabled
|
|
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
|
filtering disabled
|
|
Buffer logging: level debugging, 56 messages logged, xml disabled,
|
|
filtering disabled
|
|
Exception Logging: size (4096 bytes)
|
|
Count and timestamp logging messages: disabled
|
|
File logging: disabled
|
|
Persistent logging: disabled
|
|
|
|
No active filter modules.
|
|
|
|
Trap logging: level informational, 59 message lines logged
|
|
Logging Source-Interface: VRF Name:
|
|
|
|
Log Buffer (4096 bytes):
|
|
TED: Switch 3 R0/0: stack_mgr: Switch 3 has been elected ACTIVE.
|
|
*Jun 7 09:46:26.618: %HMANRP-6-EMP_NO_ELECTION_INFO: Could not elect active EMP switch, setting emp active switch to 0: EMP_RELAY: Could not elect switch with mgmt port UP
|
|
*Jun 7 09:46:27.021: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi20/3, changed state to up
|
|
*Jun 7 09:46:27.022: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC20/1, changed state to up
|
|
*Jun 7 09:46:27.022: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
|
*Jun 7 09:46:27.023: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN20/2, changed state to up
|
|
*Jun 7 09:46:28.977: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
|
|
*Jun 7 09:46:29.957: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
|
*Jun 7 09:46:31.616: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
|
*Jun 7 09:46:31.624: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
|
*Jun 7 09:46:33.601: %SYS-5-RESTART: System restarted --
|
|
Cisco IOS Software [Fuji], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.9.5, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2020 by Cisco Systems, Inc.
|
|
Compiled Thu 30-Jan-20 18:17 by mcpre
|
|
*Jun 7 09:46:34.970: %LINK-3-UPDOWN: Interface GigabitEthernet3/1/1, changed state to down
|
|
*Jun 7 09:46:34.971: %LINK-3-UPDOWN: Interface GigabitEthernet3/1/2, changed state to down
|
|
*Jun 7 09:46:34.974: %LINK-3-UPDOWN: Interface GigabitEthernet3/1/3, changed state to down
|
|
*Jun 7 09:46:34.974: %LINK-3-UPDOWN: Interface GigabitEthernet3/1/4, changed state to down
|
|
*Jun 7 09:46:34.977: %LINK-3-UPDOWN: Interface TenGigabitEthernet3/1/1, changed state to down
|
|
*Jun 7 09:46:34.977: %LINK-3-UPDOWN: Interface TenGigabitEthernet3/1/2, changed state to down
|
|
*Jun 7 09:46:34.980: %LINK-3-UPDOWN: Interface TenGigabitEthernet3/1/3, changed state to down
|
|
*Jun 7 09:46:34.980: %LINK-3-UPDOWN: Interface TenGigabitEthernet3/1/4, changed state to down
|
|
*Jun 7 09:46:35.593: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
|
*Jun 7 09:46:35.971: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet3/1/1, changed state to down
|
|
*Jun 7 09:46:35.973: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet3/1/2, changed state to down
|
|
*Jun 7 09:46:35.974: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet3/1/3, changed state to down
|
|
*Jun 7 09:46:35.974: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet3/1/4, changed state to down
|
|
*Jun 7 09:46:35.978: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet3/1/1, changed state to down
|
|
*Jun 7 09:46:35.978: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet3/1/2, changed state to down
|
|
*Jun 7 09:46:35.983: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet3/1/3, changed state to down
|
|
*Jun 7 09:46:35.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet3/1/4, changed state to down
|
|
*Jun 7 09:46:37.924: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
|
|
|
*Jun 7 09:46:38.044: %ONEP_BASE-6-SS_ENABLED: ONEP: Service set Base was enabled by Default
|
|
*Jun 7 09:46:38.924: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
|
*Jun 7 09:46:39.113: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
|
|
*Jun 7 09:46:44.629: %PKI-2-NON_AUTHORITATIVE_CLOCK: PKI functions can not be initialized until an authoritative time source, like NTP, can be obtained.
|
|
*Jun 7 09:46:44.725: %CRYPTO_ENGINE-5-KEY_ADDITION: A key named CISCO_IDEVID_SUDI_LEGACY has been generated or imported by pki-sudi
|
|
*Jun 7 09:46:44.870: %CRYPTO_ENGINE-5-KEY_ADDITION: A key named CISCO_IDEVID_SUDI has been generated or imported by pki-sudi
|
|
*Jun 7 09:46:56.952: %PLATFORM_PM-6-FRULINK_INSERTED: 4x1G uplink module inserted in the switch 3 slot 1###show env all
|
|
Switch 3 FAN 1 is OK
|
|
Switch 3 FAN 2 is OK
|
|
Switch 3 FAN 3 is OK
|
|
FAN PS-1 is OK
|
|
FAN PS-2 is NOT PRESENT
|
|
Switch 3: SYSTEM TEMPERATURE is OK
|
|
Inlet Temperature Value: 24 Degree Celsius
|
|
|
|
Temperature State: GREEN
|
|
Yellow Threshold : 46 Degree Celsius
|
|
Red Threshold : 56 Degree Celsius
|
|
|
|
Hotspot Temperature Value: 38 Degree Celsius
|
|
Temperature State: GREEN
|
|
Yellow Threshold : 105 Degree Celsius
|
|
Red Threshold : 125 Degree Celsius
|
|
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
|
-- ------------------ ---------- --------------- ------- ------- -----
|
|
3A PWR-C1-350WAC LIT18200BHY OK Good Good 350
|
|
3B Not Present
|