CiscoTool_v1/netmiko_Api/public/filesTest/20230908-AUTO-Session.AUS-2...

210 lines
8.6 KiB
Plaintext

clear line 13
[confirm]
[OK]
VN_2911TS#no
% Incomplete command.
Switch#
Switch####show inv
NAME: "3", DESCR: "WS-C3750X-48P"
PID: WS-C3750X-48PF-S , VID: V05 , SN: FDO1729Z0PM
NAME: "Switch 3 - Power Supply 1", DESCR: "FRU Power Supply"
PID: C3KX-PWR-1100WAC , VID: V02L , SN: LIT17231824
### show ver
Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 15.2(4)E10b, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2021 by Cisco Systems, Inc.
Compiled Wed 10-Mar-21 15:03 by prod_rel_team
ROM: Bootstrap program is C3750E boot loader
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(58r)SE1, RELEASE SOFTWARE (fc1)
Switch uptime is 2 hours, 51 minutes
System returned to ROM by power-on
System image file is "flash:/c3750e-universalk9-mz.152-4.E10b.bin"
Last reload reason: power-on
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
License Level: ipbase
License Type: Permanent
Next reload license Level: ipbase
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
Processor board ID FDO1729Z0PM
Last reset from power-on
1 Virtual Ethernet interface
1 FastEthernet interface
52 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : C0:8C:60:3E:BA:00
Motherboard assembly number : 73-12553-10
Motherboard serial number : FDO17290E53
Model revision number : A0
Motherboard revision number : B0
Model number : WS-C3750X-48PF-S
Daughterboard assembly number : 800-32727-03
Daughterboard serial number : FDO172830F7
System serial number : FDO1729Z0PM
Top Assembly Part Number : 800-31324-08
Top Assembly Revision Number : C0
Version ID : V05
CLEI Code Number : COMJZ00ARE
Hardware Board Revision Number : 0x05
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 3 54 WS-C3750X-48P 15.2(4)E10b C3750E-UNIVERSALK9-M
Configuration register is 0xF
### show logging
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 32 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 35 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 38 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
*Mar 1 00:00:07.121: Read env variable - LICENSE_BOOT_LEVEL =
*Jan 2 00:00:05.981: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
*Jan 2 00:01:14.968: %STACKMGR-4-SWITCH_ADDED: Switch 3 has been ADDED to the stack
*Jan 2 00:01:17.946: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jan 2 00:01:17.946: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Jan 2 00:01:25.437: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
*Jan 2 00:01:33.423: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
*Jan 2 00:01:33.423: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 2 inserted
*Jan 2 00:01:33.423: %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding
*Jan 2 00:01:54.017: %STACKMGR-5-SWITCH_READY: Switch 3 is READY
*Jan 2 00:01:54.017: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 3 has changed to state DOWN
*Jan 2 00:01:54.017: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 3 has changed to state DOWN
*Jan 2 00:01:54.722: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
*Jan 2 00:01:55.209: %STACKMGR-5-MASTER_READY: Master Switch 3 is READY
*Jan 2 00:01:56.794: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 15.2(4)E10b, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2021 by Cisco Systems, Inc.
Compiled Wed 10-Mar-21 15:03 by prod_rel_team
*Jan 2 00:01:58.774: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
*Jan 2 00:01:59.780: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Jan 2 00:02:04.881: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
*Jan 2 00:02:05.904: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
*Jan 2 00:02:09.587: %PLATFORM_ENV-1-FAN: Faulty fan detected
*Jan 2 00:03:30.554: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:03:41.660: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:03:43.187: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:03:44.747: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:03:45.536: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:07:09.421: %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply B is not responding
*Jan 2 00:26:54.010: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:27:05.116: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:27:16.483: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:27:18.043: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:27:28.386: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:36:01.173: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:36:04.143: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:36:05.108: %SYS-5-CONFIG_I: Configured from console by console
*Jan 2 00:36:16.113: %SYS-5-CONFIG_I: Configured from console by console### show post
Stored system POST messages:
Switch 3
---------
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: MA BIST : Begin
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: SF ASIC BIST : Begin
POST: SF ASIC BIST : End, Status Passed
POST: Switch Fabric Memory Tests : Begin
POST: Switch Fabric Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: PortASIC Macsec Loopback Tests : Begin
POST: PortASIC Macsec Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
### show env all
FAN 1 is OK
FAN 2 is OK
FAN PS-1 is OK
FAN PS-2 is NOT INITIALIZED
SYSTEM TEMPERATURE is OK
System Temperature Value: 23 Degree Celsius
System Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 60 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
3A C3KX-PWR-1100WAC LIT17231824 OK Good Good 1100/0
3B UNKNOWN unknown No Input Power Bad N/A 0/0
SW Status RPS Name RPS Serial# RPS Port#
-- ------------- ---------------- ----------- ---------
3 Not Present <>