=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 23:57:11 UTC Thu Jul 20 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:11 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 19 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 25 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 48 Celsius, Normal
Power Supply Unit temperature: 26 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.6 W
Total System Power consumption is: 48.6 W
Environmental information last updated 00:00:19 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.763: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 20 23:59:32.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 20 23:59:39.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 20 23:59:50.387: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 20 23:59:50.387: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 20 23:59:50.391: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 20 23:59:50.391: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 20 23:59:51.579: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 20 23:59:51.579: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 20 23:59:51.579: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 20 23:59:52.331: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 00:00:00.715: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 00:00:00.715: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 00:00:00.715: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 00:00:00.715: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 00:00:01.751: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 00:00:01.751: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 00:00:03.927: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 00:00:03.967: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 00:00:04.579: %SYS-6-BOOTTIME: Time taken to reboot after reload = 173 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset administratively down down
GigabitEthernet0/1 unassigned YES unset administratively down down
GigabitEthernet0/2 unassigned YES unset administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Router uptime is 5 minutes
System returned to ROM by power-on
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: power-on
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL174510ZN
3 Gigabit Ethernet interfaces
1 terminal line
1 Virtual Private Network (VPN) Module
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL174510ZN
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security securityk9 Permanent securityk9
uc uck9 Permanent uck9
data None None None
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:05:33 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC17428K3K
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : C1
Deviation Number : 130603
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL174510ZN
Chassis MAC Address : 78da.6e42.4a48
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : ART1904F3KX
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 19 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 25 Celsius, Normal
Exhaust Right temperature: 22 Celsius, Normal
CPU temperature: 47 Celsius, Normal
Power Supply Unit temperature: 22 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 50.1 W
Total System Power consumption is: 50.1 W
Environmental information last updated 00:00:26 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 27 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 27 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 30 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.935: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:05.091: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = securityk9 and License = securityk9
*Jan 2 00:00:05.251: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jul 21 00:11:31.247: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 00:11:37.675: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 00:11:49.123: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Initialized
*Jul 21 00:11:49.131: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Enabled
*Jul 21 00:11:50.015: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 00:11:50.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 00:11:50.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 00:11:50.015: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 00:11:51.147: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 00:11:51.147: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 00:11:51.147: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 00:11:51.967: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 00:16:16.559: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 00:16:16.559: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 00:16:16.559: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 00:16:16.559: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 00:16:17.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 00:16:17.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 00:16:18.151: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 00:16:18.191: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 00:16:18.819: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 00:16:18.819: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 00:16:18.819: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 00:16:18.819: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset administratively down down
GigabitEthernet0/1 unassigned YES unset administratively down down
GigabitEthernet0/2 unassigned YES unset administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPEL=============================================================
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
RAM: 0.25G
Flash: 0.00G
=================================================================
Switch####show inv
NAME: "1", DESCR: "WS-C3750X-48P"
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
###show ver
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
ROM: Bootstrap program is C3750E boot loader
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
Switch uptime is 1 day, 16 hours, 45 minutes
System returned to ROM by power-on
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
License Level: ipbase
License Type: Permanent
Next reload license Level: ipbase
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
Processor board ID FDO1628R0CS
Last reset from power-on
1 Virtual Ethernet interface
1 FastEthernet interface
52 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 30:F7:0D:88:A0:00
Motherboard assembly number : 73-12553-06
Motherboard serial number : FDO1628033U
Model revision number : A0
Motherboard revision number : A0
Model number : WS-C3750X-48PF-S
Daughterboard assembly number : 800-32727-03
Daughterboard serial number : FDO16271VNS
System serial number : FDO1628R0CS
Top Assembly Part Number : 800-31324-03
Top Assembly Revision Number : B0
Version ID : V03
CLEI Code Number : COMJZ00ARC
Hardware Board Revision Number : 0x04
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
Configuration register is 0xF
###show post
Stored system POST messages:
Switch 1
---------
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: MA BIST : Begin
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: SF ASIC BIST : Begin
POST: SF ASIC BIST : End, Status Passed
POST: Switch Fabric Memory Tests : Begin
POST: Switch Fabric Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: PortASIC Macsec Loopback Tests : Begin
POST: PortASIC Macsec Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 64 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 64 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 67 message lines logged
Log Buffer (4096 bytes):
Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:30.051: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:31.502: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
*Mar 1 00:01:31.981: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
*Mar 1 00:01:32.987: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:01:38.062: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
*Mar 1 00:01:39.069: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
*Mar 1 00:02:00.099: %LINK-5-CHANGED: Interface FastEthernet0, changed state to administratively down
*Mar 1 00:02:01.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:03:39.789: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 00:03:50.820: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 00:03:52.465: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 00:03:53.345: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 00:03:54.209: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Mar 1 00:04:04.334: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 16:10:03.776: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 16:10:14.798: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 16:10:16.342: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 16:10:17.223: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 16:10:28.178: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 18:27:26.875: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 18:27:37.948: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 18:27:39.432: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 18:27:49.792: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 18:27:51.353: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 19:42:00.108: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 19:42:11.215: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 19:42:12.767: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 19:42:13.689: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 19:42:24.636: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 22:52:20.141: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to up
*Mar 1 22:52:21.172: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to up
*Mar 1 22:52:27.682: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to down
*Mar 1 22:52:28.680: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down
*Mar 1 23:22:08.776: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:22:20.722: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:22:22.215: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:22:32.558: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:22:34.177: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:32:59.221: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:33:01.393: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:33:01.871: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:33:13.431: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 23:33:15.067: %SYS-5-CONFIG_I: Configured from console by console
*Mar 2 00:55:19.842: %SYS-5-CONFIG_I: Configured from console by console
*Mar 2 00:55:31.813: %SYS-5-CONFIG_I: Configured from console by console
*Mar 2 00:55:33.381: %SYS-5-CONFIG_I: Configured from console by console
*Mar 2 00:55:43.775: %SYS-5-CONFIG_I: Configured from console by console
*Mar 2 00:55:45.276: %SYS-5-CONFIG_I: Configured from console by console###show env all
FAN 1 is OK
FAN 2 is OK
FAN PS-1 is OK
FAN PS-2 is NOT PRESENT
SYSTEM TEMPERATURE is OK
System Temperature Value: 29 Degree Celsius
System Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 60 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
--- ------------------ ---------- --------------- ------- ------- -----
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
1B Not Present
SW Status RPS Name RPS Serial# RPS Port#
-- ------------- ---------------- ----------- ---------
1 Not Present <>
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
FastEthernet0 unassigned YES unset administratively down down
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/0/25 unassigned YES unset down down
GigabitEthernet1/0/26 unassigned YES unset down down
GigabitEthernet1/0/27 unassigned YES unset down down
GigabitEthernet1/0/28 unassigned YES unset down down
GigabitEthernet1/0/29 unassigned YES unset down down
GigabitEthernet1/0/30 unassigned YES unset down down
GigabitEthernet1/0/31 unassigned YES unset down down
GigabitEthernet1/0/32 unassigned YES unset down down
GigabitEthernet1/0/33 unassigned YES unset down down
GigabitEthernet1/0/34 unassigned YES unset down down
GigabitEthernet1/0/35 unassigned YES unset down down
GigabitEthernet1/0/36 unassigned YES unset down down
GigabitEthernet1/0/37 unassigned YES unset down down
GigabitEthernet1/0/38 unassigned YES unset down down
GigabitEthernet1/0/39 unassigned YES unset down down
GigabitEthernet1/0/40 unassigned YES unset down down
GigabitEthernet1/0/41 unassigned YES unset down down
GigabitEthernet1/0/42 unassigned YES unset down down
GigabitEthernet1/0/43 unassigned YES unset down down
GigabitEthernet1/0/44 unassigned YES unset down down
GigabitEthernet1/0/45 unassigned YES unset down down
GigabitEthernet1/0/46 unassigned YES unset down down
GigabitEthernet1/0/47 unassigned YES unset down down
GigabitEthernet1/0/48 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-48
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================Faulty=============================================================
PID: WS-C3850-24P , VID: V08 , SN: FCW2239F0FC
RAM: 4.00G
Flash: 1.53G
=================================================================
Faulty:
system returned to rom by power failure at 14:50:25 utc mon sep 21 2020
last reload reason: power failure
======================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS Software, IOS-XE Software, Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 03.07.04E RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2016 by Cisco Systems, Inc.
Compiled Thu 19-May-16 11:48 by prod_rel_team
Cisco IOS-XE software, Copyright (c) 2005-2015 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0.
(http://www.gnu.org/licenses/gpl-2.0.html) For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Power Failure at 14:50:25 UTC Mon Sep 21 2020
System image file is "flash:packages.conf"
Last reload reason: Power Failure
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
License Level: Ipbase
License Type: Permanent
Next reload license Level: Ipbase
cisco WS-C3850-24P (MIPS) processor with 4194304K bytes of physical memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of Dummy USB Flash at usbflash0:.
0K bytes of at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 03.07.04E cat3k_caa-universalk9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 24 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 24 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 26 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (16384 bytes):
*Jul 20 23:57:33.500: *%INIT-7-SWITCH_BOOTING: 1 wcm: Switch booting...
*Jul 20 23:58:10.207: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 20 23:58:10.208: %LINK-3-UPDOWN: Interface LIIN0, changed state to up
*Jul 20 23:58:10.208: %NGWC_PLATFORM_FEP-6-FRU_PS_OIR: Switch 1: FRU power supply A inserted
*Jul 20 23:58:10.209: %NGWC_PLATFORM_FEP-6-FRU_PS_OIR: Switch 1: FRU power supply B inserted
*Jul 20 23:58:10.281: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
*Jul 20 23:58:12.602: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 20 23:58:12.602: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN0, changed state to up
*Jul 20 23:58:14.775: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 20 23:58:21.508: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 20 23:58:28.640: %STACKMGR-6-ACTIVE_READY: 1 stack-mgr: Active switch 1 is ready. System has been configured
*Jul 20 23:58:28.889: %SYS-5-RESTART: System restarted --
Cisco IOS Software, IOS-XE Software, Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 03.07.04E RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2016 by Cisco Systems, Inc.
Compiled Thu 19-May-16 11:48 by prod_rel_team
*Jul 20 23:58:28.899: %AUTHMGR_SPI-6-START: Auth Manager SPI server started
*Jul 20 23:58:30.511: %LINK-5-CHANGED: Interface Vlan1, changed state to administratively down
*Jul 20 23:58:31.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 20 23:58:31.674: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 20 23:58:31.675: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 20 23:58:31.675: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 20 23:58:31.675: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 20 23:58:31.675: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 20 23:58:31.675: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 20 23:58:31.676: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 20 23:58:39.083: %SSH-5-ENABLED: SSH 1.99 has been enabled###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Interface IP-Address OK? Method Status Protocol
GigabitEthernet0/0 unassigned YES unset down down
Vlan1 unassigned YES unset administratively down down
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#
*Jul 20 23:59:28.833: %SYS-5-CONFIG_I: Configured from console by console
*Jul 20 23:59:29.513: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================DPELP=============================================================
iscoasa###show inv
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
ciscoasa###show version
Cisco Adaptive Security Appliance Software Version 9.5(1)
Compiled on Wed 12-Aug-15 12:18 PDT by builders
System image file is "disk0:/asa951-lfbff-k8.SPA"
Config file at boot was "startup-config"
ciscoasa up 16 hours 51 mins
Hardware: ASA5516, 8192 MB RAM, CPU Atom C2000 series 2416 MHz, 1 CPU (8 cores)
Internal ATA Compact Flash, 8192MB
BIOS Flash unknown @ 0x0, 0KB
Encryption hardware device : Cisco ASA Crypto on-board accelerator (revision 0x1)
Number of accelerators: 1
1: Ext: GigabitEthernet1/1 : address is ecbd.1d5f.a632, irq 255
2: Ext: GigabitEthernet1/2 : address is ecbd.1d5f.a633, irq 255
3: Ext: GigabitEthernet1/3 : address is ecbd.1d5f.a634, irq 255
4: Ext: GigabitEthernet1/4 : address is ecbd.1d5f.a635, irq 255
5: Ext: GigabitEthernet1/5 : address is ecbd.1d5f.a636, irq 255
6: Ext: GigabitEthernet1/6 : address is ecbd.1d5f.a637, irq 255
7: Ext: GigabitEthernet1/7 : address is ecbd.1d5f.a638, irq 255
8: Ext: GigabitEthernet1/8 : address is ecbd.1d5f.a639, irq 255
9: Int: Internal-Data1/1 : address is ecbd.1d5f.a631, irq 255
<--- More --->
10: Int: Internal-Data1/2 : address is 0000.0001.0002, irq 0
11: Int: Internal-Control1/1 : address is 0000.0001.0001, irq 0
12: Int: Internal-Data1/3 : address is 0000.0001.0003, irq 0
13: Ext: Management1/1 : address is ecbd.1d5f.a631, irq 0
The Running Activation Key feature: 500 AnyConnect Premium sessions exceed the limit on the platform, reduced to 300 AnyConnect Premium sessions.
Licensed features for this platform:
Maximum Physical Interfaces : Unlimited perpetual
Maximum VLANs : 150 perpetual
Inside Hosts : Unlimited perpetual
Failover : Active/Active perpetual
Encryption-DES : Enabled perpetual
Encryption-3DES-AES : Enabled perpetual
Security Contexts : 2 perpetual
GTP/GPRS : Disabled perpetual
AnyConnect Premium Peers : 300 perpetual
AnyConnect Essentials : Disabled perpetual
Other VPN Peers : 300 perpetual
Total VPN Peers : 300 perpetual
Shared License : Disabled perpetual
AnyConnect for Mobile : Enabled perpetual
AnyConnect for Cisco VPN Phone : Enabled perpetual
Advanced Endpoint Assessment : Enabled perpetual
Total UC Proxy Sessions : 1000 perpetual
<--- More --->
Botnet Traffic Filter : Disabled perpetual
<--- More --->
Cluster : Disabled perpetual
VPN Load Balancing : Enabled perpetual
Serial Number: JAD193302L9
Running Permanent Activation Key: 0x803fd871 0x648697a2 0x88b2913c 0xbf282ce4 0x8233308c
Configuration register is 0x1
Image type : Release
Key Version : A
Configuration last modified by enable_15 at 09:46:51.179 UTC Thu Jul 20 2023
ciscoasa# diag
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show env all
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show log
Syslog logging: disabled
Facility: 20
Timestamp logging: disabled
Hide Username logging: enabled
Standby logging: disabled
Debug-trace logging: disabled
Console logging: disabled
Monitor logging: disabled
Buffer logging: disabled
Trap logging: disabled
Permit-hostdown logging: disabled
History logging: disabled
Device ID: disabled
Mail logging: disabled
ASDM logging: disabled
ciscoasa###show power
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa#
ciscoasa#
ciscoasa#
ciscoasa#
^
ERROR: % Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
GigabitEthernet1/1 unassigned YES unset down down
GigabitEthernet1/2 unassigned YES unset down down
GigabitEthernet1/3 unassigned YES unset down down
GigabitEthernet1/4 unassigned YES unset down down
GigabitEthernet1/5 unassigned YES unset down down
GigabitEthernet1/6 unassigned YES unset down down
GigabitEthernet1/7 unassigned YES unset down down
GigabitEthernet1/8 unassigned YES unset down down
Internal-Control1/1 127.0.1.1 YES unset up up
Internal-Data1/1 unassigned YES unset up down
Internal-Data1/2 unassigned YES unset down down
Internal-Data1/3 unassigned YES unset up up
Management1/1 unassigned YES unset down down
configure terminal
ciscoasa(config)# interface GigabitEthernet1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/2
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/3
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/4
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/5
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/6
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/7
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/8
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Control1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/2
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/3
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Management1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa#
Finish
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 00:16:14 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:07 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 18 Celsius, Normal
Intake Left temperature: 22 Celsius, Normal
Exhaust Right(Bezel) temperature: 25 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 47 Celsius, Normal
Power Supply Unit temperature: 25 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.7 W
Total System Power consumption is: 48.7 W
Environmental information last updated 00:00:21 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.767: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.943: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.103: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 00:18:40.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 00:18:47.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 00:18:58.371: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 00:18:58.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 00:18:58.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 00:18:58.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 00:18:59.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 00:18:59.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 00:18:59.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 00:19:00.787: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 00:19:02.775: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 00:19:02.775: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 00:19:02.775: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 00:19:02.775: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 00:19:03.807: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 00:19:03.807: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 00:19:06.015: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 00:19:06.055: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 00:19:06.667: %SYS-6-BOOTTIME: Time taken to reboot after reload = 167 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/1 unassigned YES NVRAM administratively down down
GigabitEthernet0/2 unassigned YES NVRAM administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPEL=============================================================
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
RAM: 0.25G
Flash: 0.00G
=================================================================
Switch####show inv
NAME: "1", DESCR: "WS-C3750X-48P"
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
###show ver
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
ROM: Bootstrap program is C3750E boot loader
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
Switch uptime is 2 minutes
System returned to ROM by power-on
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
License Level: ipbase
License Type: Permanent
Next reload license Level: ipbase
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
Processor board ID FDO1628R0CS
Last reset from power-on
1 Virtual Ethernet interface
1 FastEthernet interface
52 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 30:F7:0D:88:A0:00
Motherboard assembly number : 73-12553-06
Motherboard serial number : FDO1628033U
Model revision number : A0
Motherboard revision number : A0
Model number : WS-C3750X-48PF-S
Daughterboard assembly number : 800-32727-03
Daughterboard serial number : FDO16271VNS
System serial number : FDO1628R0CS
Top Assembly Part Number : 800-31324-03
Top Assembly Revision Number : B0
Version ID : V03
CLEI Code Number : COMJZ00ARC
Hardware Board Revision Number : 0x04
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
Configuration register is 0xF
###show post
Stored system POST messages:
Switch 1
---------
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: MA BIST : Begin
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: SF ASIC BIST : Begin
POST: SF ASIC BIST : End, Status Passed
POST: Switch Fabric Memory Tests : Begin
POST: Switch Fabric Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: PortASIC Macsec Loopback Tests : Begin
POST: PortASIC Macsec Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 21 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 21 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 24 message lines logged
Log Buffer (4096 bytes):
*Mar 1 00:00:05.133: Read env variable - LICENSE_BOOT_LEVEL =
*Mar 1 00:00:05.930: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
*Mar 1 00:00:57.914: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
*Mar 1 00:01:00.540: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Mar 1 00:01:00.540: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:01:05.145: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
*Mar 1 00:01:06.043: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
*Mar 1 00:01:06.043: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
*Mar 1 00:01:08.677: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
*Mar 1 00:01:27.275: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
*Mar 1 00:01:27.275: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
*Mar 1 00:01:27.275: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
*Mar 1 00:01:28.608: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
*Mar 1 00:01:29.791: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
*Mar 1 00:01:29.867: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:29.867: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:31.494: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
*Mar 1 00:01:31.788: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
*Mar 1 00:01:32.794: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:01:38.842: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
*Mar 1 00:01:39.857: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up###show env all
FAN 1 is OK
FAN 2 is OK
FAN PS-1 is OK
FAN PS-2 is NOT PRESENT
SYSTEM TEMPERATURE is OK
System Temperature Value: 29 Degree Celsius
System Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 60 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
--- ------------------ ---------- --------------- ------- ------- -----
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
1B Not Present
SW Status RPS Name RPS Serial# RPS Port#
-- ------------- ---------------- ----------- ---------
1 Not Present <>
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
FastEthernet0 unassigned YES unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/0/25 unassigned YES unset down down
GigabitEthernet1/0/26 unassigned YES unset down down
GigabitEthernet1/0/27 unassigned YES unset down down
GigabitEthernet1/0/28 unassigned YES unset down down
GigabitEthernet1/0/29 unassigned YES unset down down
GigabitEthernet1/0/30 unassigned YES unset down down
GigabitEthernet1/0/31 unassigned YES unset down down
GigabitEthernet1/0/32 unassigned YES unset down down
GigabitEthernet1/0/33 unassigned YES unset down down
GigabitEthernet1/0/34 unassigned YES unset down down
GigabitEthernet1/0/35 unassigned YES unset down down
GigabitEthernet1/0/36 unassigned YES unset down down
GigabitEthernet1/0/37 unassigned YES unset down down
GigabitEthernet1/0/38 unassigned YES unset down down
GigabitEthernet1/0/39 unassigned YES unset down down
GigabitEthernet1/0/40 unassigned YES unset down down
GigabitEthernet1/0/41 unassigned YES unset down down
GigabitEthernet1/0/42 unassigned YES unset down down
GigabitEthernet1/0/43 unassigned YES unset down down
GigabitEthernet1/0/44 unassigned YES unset down down
GigabitEthernet1/0/45 unassigned YES unset down down
GigabitEthernet1/0/46 unassigned YES unset down down
GigabitEthernet1/0/47 unassigned YES unset down down
GigabitEthernet1/0/48 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-48
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#
*Mar 1 00:03:08.584: %SYS-5-CONFIG_I: Configured from console by console
*Mar 1 00:03:09.230: %SYS-5-CONFIG_I: Configured from console by consoleend
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================Error=============================================================
Connection Refused xxError
(1) Connection exists on device
(2) Your connection is interrupted by other connection
=============================================================loadingIOS=============================================================
clear line 22
[confirm]
[OK]
AU-dev#connect p5
Trying p5 (1.1.1.1, 2022)... Open
rommon 1 > show info
monitor: command "show" not found
rommon 2 > set
PS1=rommon ! >
RTC_STAT=0
TFTP_RETRY_COUNT=20
WARM_REBOOT=FALSE
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
DEFAULT_GATEWAY=172.16.5.2
IP_ADDRESS=172.16.19.105
IP_SUBNET_MASK=255.255.0.0
TFTP_SERVER=192.168.5.7
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
?=0
RELOAD_TYPE=1
BSI=0
RANDOM_NUM=1284337865
RET_2_RTS=01:05:03 UTC Fri Jul 21 2023
RET_2_RCALTS=1689901503
rommon 3 > showmon
Last Reset Reason: System Reset
ReadOnly ROMMON version is:
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 2011 by cisco Systems, Inc.
No upgrade ROMMON version present
ReadOnly ROMMON currently running
ReadOnly ROMMON is selected for next boot
rommon 4 > confreg
Configuration Summary
(Virtual Configuration Register: 0x2142)
enabled are:
load rom after netboot fails
ignore system config info
console baud: 9600
boot: image specified by the boot system commands
or default to: cisco2-CISCO2911/K9
do you wish to change the configuration? y/n [n]: n
rommon 5 >
rommon 5 >
rommon 5 > confreg 0x2142
rommon 6 > reset
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 01:29:09 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL174510ZN
3 Gigabit Ethernet interfaces
1 terminal line
1 Virtual Private Network (VPN) Module
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL174510ZN
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security securityk9 Permanent securityk9
uc uck9 Permanent uck9
data None None None
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:42 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC17428K3K
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : C1
Deviation Number : 130603
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL174510ZN
Chassis MAC Address : 78da.6e42.4a48
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : ART1904F3KX
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan Rotation Alert: Total 2 Fan Low RPM
Fan 1 OK, Maximum speed setting
Fan 2 OK, Maximum speed setting
Fan 3 OK, Maximum speed setting
Fan 4 Low RPM
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 18 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 23 Celsius, Normal
Exhaust Right temperature: 21 Celsius, Normal
CPU temperature: 41 Celsius, Normal
Power Supply Unit temperature: 21 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 81.2 W
Total System Power consumption is: 81.2 W
Environmental information last updated 00:00:27 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 29 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 29 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 32 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = securityk9 and License = securityk9
*Jan 2 00:00:05.255: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.595: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
*Jul 21 01:31:18.635: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:31:25.063: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:31:36.515: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Initialized
*Jul 21 01:31:36.519: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Enabled
*Jul 21 01:31:37.407: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:31:39.707: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:31:42.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:31:42.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:31:43.267: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:31:43.307: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:31:43.923: %SYS-6-BOOTTIME: Time taken to reboot after reload = 153 seconds
*Jul 21 01:31:44.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/1 unassigned YES NVRAM administratively down down
GigabitEthernet0/2 unassigned YES NVRAM administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Router uptime is 2 minutes
System returned to ROM by reload at 01:29:09 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL174510ZN
3 Gigabit Ethernet interfaces
1 terminal line
1 Virtual Private Network (VPN) Module
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL174510ZN
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security securityk9 Permanent securityk9
uc uck9 Permanent uck9
data None None None
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:02:35 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC17428K3K
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : C1
Deviation Number : 130603
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL174510ZN
Chassis MAC Address : 78da.6e42.4a48
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : ART1904F3KX
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan Rotation Alert: Total 2 Fan Low RPM
Fan 1 OK, Maximum speed setting
Fan 2 OK, Maximum speed setting
Fan 3 OK, Maximum speed setting
Fan 4 Low RPM
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 18 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 23 Celsius, Normal
Exhaust Right temperature: 21 Celsius, Normal
CPU temperature: 41 Celsius, Normal
Power Supply Unit temperature: 21 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 82.8 W
Total System Power consumption is: 82.8 W
Environmental information last updated 00:00:19 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 35 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 35 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 38 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = securityk9 and License = securityk9
*Jan 2 00:00:05.255: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.595: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
*Jul 21 01:31:18.635: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:31:25.063: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:31:36.515: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Initialized
*Jul 21 01:31:36.519: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Enabled
*Jul 21 01:31:37.407: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:31:37.407: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:31:38.539: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:31:39.707: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:31:41.715: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:31:42.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:31:42.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:31:43.267: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:31:43.307: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:31:43.923: %SYS-6-BOOTTIME: Time taken to reboot after reload = 153 seconds
*Jul 21 01:31:44.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 01:31:44.551: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 01:33:20.719: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 01:33:22.487: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:33:22.531: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:33:22.575: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:33:26.543: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:33:27.543: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM up up
GigabitEthernet0/1 unassigned YES NVRAM down down
GigabitEthernet0/2 unassigned YES NVRAM down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 01:05:03 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:18 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 49 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.7 W
Total System Power consumption is: 48.7 W
Environmental information last updated 00:00:24 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.779: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.955: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.119: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 01:19:16.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:19:23.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:19:34.367: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:19:34.367: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:19:34.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:19:34.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:19:36.315: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:19:48.519: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:19:48.519: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:19:51.027: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:19:51.067: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:19:51.683: %SYS-6-BOOTTIME: Time taken to reboot after reload = 889 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset administratively down down
GigabitEthernet0/1 unassigned YES unset administratively down down
GigabitEthernet0/2 unassigned YES unset administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 2 minutes
System returned to ROM by reload at 01:05:03 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:02:10 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 49 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 50.7 W
Total System Power consumption is: 50.7 W
Environmental information last updated 00:00:15 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 31 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.779: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.955: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.119: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 01:19:16.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:19:23.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:19:34.367: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:19:34.367: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:19:34.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:19:34.371: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:19:35.559: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:19:36.315: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:19:47.519: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:19:48.519: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:19:48.519: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:19:51.027: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:19:51.067: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:19:51.683: %SYS-6-BOOTTIME: Time taken to reboot after reload = 889 seconds
*Jul 21 01:20:54.299: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 01:20:56.071: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:20:56.115: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:20:56.155: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:21:00.367: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:21:01.367: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset up up
GigabitEthernet0/1 unassigned YES unset down down
GigabitEthernet0/2 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
iscoasa###show inv
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
ciscoasa###show version
Cisco Adaptive Security Appliance Software Version 9.5(1)
Compiled on Wed 12-Aug-15 12:18 PDT by builders
System image file is "disk0:/asa951-lfbff-k8.SPA"
Config file at boot was "startup-config"
ciscoasa up 18 hours 19 mins
Hardware: ASA5516, 8192 MB RAM, CPU Atom C2000 series 2416 MHz, 1 CPU (8 cores)
Internal ATA Compact Flash, 8192MB
BIOS Flash unknown @ 0x0, 0KB
Encryption hardware device : Cisco ASA Crypto on-board accelerator (revision 0x1)
Number of accelerators: 1
1: Ext: GigabitEthernet1/1 : address is ecbd.1d5f.a632, irq 255
2: Ext: GigabitEthernet1/2 : address is ecbd.1d5f.a633, irq 255
3: Ext: GigabitEthernet1/3 : address is ecbd.1d5f.a634, irq 255
4: Ext: GigabitEthernet1/4 : address is ecbd.1d5f.a635, irq 255
5: Ext: GigabitEthernet1/5 : address is ecbd.1d5f.a636, irq 255
6: Ext: GigabitEthernet1/6 : address is ecbd.1d5f.a637, irq 255
7: Ext: GigabitEthernet1/7 : address is ecbd.1d5f.a638, irq 255
8: Ext: GigabitEthernet1/8 : address is ecbd.1d5f.a639, irq 255
9: Int: Internal-Data1/1 : address is ecbd.1d5f.a631, irq 255
<--- More --->
10: Int: Internal-Data1/2 : address is 0000.0001.0002, irq 0
11: Int: Internal-Control1/1 : address is 0000.0001.0001, irq 0
12: Int: Internal-Data1/3 : address is 0000.0001.0003, irq 0
13: Ext: Management1/1 : address is ecbd.1d5f.a631, irq 0
The Running Activation Key feature: 500 AnyConnect Premium sessions exceed the limit on the platform, reduced to 300 AnyConnect Premium sessions.
Licensed features for this platform:
Maximum Physical Interfaces : Unlimited perpetual
Maximum VLANs : 150 perpetual
Inside Hosts : Unlimited perpetual
Failover : Active/Active perpetual
Encryption-DES : Enabled perpetual
Encryption-3DES-AES : Enabled perpetual
Security Contexts : 2 perpetual
GTP/GPRS : Disabled perpetual
AnyConnect Premium Peers : 300 perpetual
AnyConnect Essentials : Disabled perpetual
Other VPN Peers : 300 perpetual
Total VPN Peers : 300 perpetual
Shared License : Disabled perpetual
AnyConnect for Mobile : Enabled perpetual
AnyConnect for Cisco VPN Phone : Enabled perpetual
Advanced Endpoint Assessment : Enabled perpetual
Total UC Proxy Sessions : 1000 perpetual
<--- More --->
Botnet Traffic Filter : Disabled perpetual
<--- More --->
Cluster : Disabled perpetual
VPN Load Balancing : Enabled perpetual
Serial Number: JAD193302L9
Running Permanent Activation Key: 0x803fd871 0x648697a2 0x88b2913c 0xbf282ce4 0x8233308c
Configuration register is 0x1
Image type : Release
Key Version : A
Configuration last modified by enable_15 at 01:10:48.458 UTC Fri Jul 21 2023
ciscoasa# diag
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show env all
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show log
Syslog logging: disabled
Facility: 20
Timestamp logging: disabled
Hide Username logging: enabled
Standby logging: disabled
Debug-trace logging: disabled
Console logging: disabled
Monitor logging: disabled
Buffer logging: disabled
Trap logging: disabled
Permit-hostdown logging: disabled
History logging: disabled
Device ID: disabled
Mail logging: disabled
ASDM logging: disabled
ciscoasa###show power
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa#
ciscoasa#
ciscoasa#
ciscoasa#
^
ERROR: % Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
GigabitEthernet1/1 unassigned YES unset down down
GigabitEthernet1/2 unassigned YES unset down down
GigabitEthernet1/3 unassigned YES unset down down
GigabitEthernet1/4 unassigned YES unset down down
GigabitEthernet1/5 unassigned YES unset down down
GigabitEthernet1/6 unassigned YES unset down down
GigabitEthernet1/7 unassigned YES unset down down
GigabitEthernet1/8 unassigned YES unset down down
Internal-Control1/1 127.0.1.1 YES unset up up
Internal-Data1/1 unassigned YES unset up down
Internal-Data1/2 unassigned YES unset down down
Internal-Data1/3 unassigned YES unset up up
Management1/1 unassigned YES unset down down
configure terminal
ciscoasa(config)# interface GigabitEthernet1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/2
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/3
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/4
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/5
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/6
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/7
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/8
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Control1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/2
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/3
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Management1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa#
Finish
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 01:36:31 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:07 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 49 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.7 W
Total System Power consumption is: 48.7 W
Environmental information last updated 00:00:21 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.763: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 01:38:57.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:39:04.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:39:15.339: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:39:17.759: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:39:20.735: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:39:20.735: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:39:23.351: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:39:23.387: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:39:24.003: %SYS-6-BOOTTIME: Time taken to reboot after reload = 168 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/1 unassigned YES NVRAM administratively down down
GigabitEthernet0/2 unassigned YES NVRAM administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 2 minutes
System returned to ROM by reload at 01:36:31 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:59 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 49 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 50.6 W
Total System Power consumption is: 50.6 W
Environmental information last updated 00:00:12 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 31 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.763: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.939: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.099: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 01:38:57.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 01:39:04.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 01:39:15.339: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:39:15.339: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:39:16.527: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:39:17.759: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 01:39:19.731: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 01:39:20.735: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 01:39:20.735: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:39:23.351: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 01:39:23.387: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 01:39:24.003: %SYS-6-BOOTTIME: Time taken to reboot after reload = 168 seconds
*Jul 21 01:40:22.819: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 01:40:24.591: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 21 01:40:24.731: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 01:40:24.731: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 01:40:28.623: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 01:40:29.623: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM up up
GigabitEthernet0/1 unassigned YES NVRAM down down
GigabitEthernet0/2 unassigned YES NVRAM down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf;
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1594073478
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689902621
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================ERROR=============================================================
Load IOS failed+
=======================================
****NO CONNECTION TO TFTP SERVER****
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch:
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf;
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1594073478
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689902621
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch: format flash:
Are you sure you want to format "flash:" (all data will be lost) (y/n)?y
Filesystem "flash:" not formatted -- invalid argument
switch: set DEFAULT_ROUTER 172.16.5.2
switch: set IP_ADDR 172.16.19.108/255.255.0.0
switch: ping 192.168.5.7
ping 192.168.5.7 with 32 bytes of data ...
Request timed out.
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 02:21:17 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:04 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 22 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 48 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.6 W
Total System Power consumption is: 48.6 W
Environmental information last updated 00:00:18 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.775: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.951: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.115: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 02:23:43.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 02:23:50.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 02:24:01.303: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 02:24:01.303: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:24:01.307: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:24:01.307: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:24:03.727: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 02:24:06.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 02:24:06.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:24:09.331: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 02:24:09.371: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 02:24:09.983: %SYS-6-BOOTTIME: Time taken to reboot after reload = 169 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/1 unassigned YES NVRAM administratively down down
GigabitEthernet0/2 unassigned YES NVRAM administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 4 minutes
System returned to ROM by reload at 02:21:17 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2102
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:04:06 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 22 Celsius, Normal
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
Exhaust Right temperature: 27 Celsius, Normal
CPU temperature: 49 Celsius, Normal
Power Supply Unit temperature: 27 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 50.4 W
Total System Power consumption is: 50.4 W
Environmental information last updated 00:00:20 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 28 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 31 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.775: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.951: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.115: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 02:23:43.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 02:23:50.059: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 02:24:01.303: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 02:24:01.303: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:24:01.307: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:24:01.307: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:24:02.495: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:24:03.727: %SYS-5-CONFIG_I: Configured from memory by console
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 02:24:05.707: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 02:24:06.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 02:24:06.743: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:24:09.331: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 02:24:09.371: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 02:24:09.983: %SYS-6-BOOTTIME: Time taken to reboot after reload = 169 seconds
*Jul 21 02:25:06.755: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 02:25:08.523: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:25:08.567: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:25:08.611: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:25:12.715: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:25:13.715: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES NVRAM administratively down down
GigabitEthernet0/0 unassigned YES NVRAM up up
GigabitEthernet0/1 unassigned YES NVRAM down down
GigabitEthernet0/2 unassigned YES NVRAM down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================loadingIOS=============================================================
clear line 24
[confirm]
[OK]
AU-dev#connect p7
Trying p7 (1.1.1.1, 2024)... Open
rommon 1 > show info
monitor: command "show" not found
rommon 2 > set
PS1=rommon ! >
RTC_STAT=0
LICENSE_BOOT_LEVEL=
TFTP_RETRY_COUNT=20
WARM_REBOOT=FALSE
LICENSE_SUITE=
BOOT=
DEFAULT_GATEWAY=172.16.5.2
IP_ADDRESS=172.16.19.105
IP_SUBNET_MASK=255.255.0.0
TFTP_SERVER=192.168.5.7
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
?=0
RELOAD_TYPE=1
BSI=0
RANDOM_NUM=834726803
RET_2_RTS=02:37:08 UTC Fri Jul 21 2023
RET_2_RCALTS=1689907028
rommon 3 > showmon
Last Reset Reason: System Reset
ReadOnly ROMMON version is:
System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 2012 by cisco Systems, Inc.
No upgrade ROMMON version present
ReadOnly ROMMON currently running
ReadOnly ROMMON is selected for next boot
rommon 4 > confreg
Configuration Summary
(Virtual Configuration Register: 0x2142)
enabled are:
load rom after netboot fails
ignore system config info
console baud: 9600
boot: image specified by the boot system commands
or default to: cisco2-CISCO2911/K9
do you wish to change the configuration? y/n [n]: n
rommon 5 >
rommon 5 >
rommon 5 > confreg 0x2142
rommon 6 > reset
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 02:37:08 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL174510ZN
3 Gigabit Ethernet interfaces
1 terminal line
1 Virtual Private Network (VPN) Module
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL174510ZN
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security securityk9 Permanent securityk9
uc uck9 Permanent uck9
data None None None
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:24 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC17428K3K
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : C1
Deviation Number : 130603
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL174510ZN
Chassis MAC Address : 78da.6e42.4a48
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : ART1904F3KX
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan Rotation Alert: Total 2 Fan Low RPM
Fan 1 OK, Maximum speed setting
Fan 2 OK, Maximum speed setting
Fan 3 OK, Maximum speed setting
Fan 4 Low RPM
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 19 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 23 Celsius, Normal
Exhaust Right temperature: 21 Celsius, Normal
CPU temperature: 41 Celsius, Normal
Power Supply Unit temperature: 21 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 80.9 W
Total System Power consumption is: 80.9 W
Environmental information last updated 00:00:25 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 29 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 29 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 32 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.935: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:05.091: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = securityk9 and License = securityk9
*Jan 2 00:00:05.247: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.587: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
*Jul 21 02:53:35.635: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 02:53:42.063: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 02:53:53.515: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Initialized
*Jul 21 02:53:53.519: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Enabled
*Jul 21 02:53:54.403: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:53:56.355: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 02:54:13.883: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 02:54:13.883: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:54:14.507: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 02:54:14.547: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 02:54:15.159: %SYS-6-BOOTTIME: Time taken to reboot after reload = 1027 seconds
*Jul 21 02:54:15.787: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset administratively down down
GigabitEthernet0/1 unassigned YES unset administratively down down
GigabitEthernet0/2 unassigned YES unset administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPEL=============================================================
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
RAM: 0.25G
Flash: 0.00G
=================================================================
Switch####show inv
NAME: "1", DESCR: "WS-C3750X-48P"
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
###show ver
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
ROM: Bootstrap program is C3750E boot loader
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
Switch uptime is 1 hour, 54 minutes
System returned to ROM by power-on
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
License Level: ipbase
License Type: Permanent
Next reload license Level: ipbase
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
Processor board ID FDO1628R0CS
Last reset from power-on
1 Virtual Ethernet interface
1 FastEthernet interface
52 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 30:F7:0D:88:A0:00
Motherboard assembly number : 73-12553-06
Motherboard serial number : FDO1628033U
Model revision number : A0
Motherboard revision number : A0
Model number : WS-C3750X-48PF-S
Daughterboard assembly number : 800-32727-03
Daughterboard serial number : FDO16271VNS
System serial number : FDO1628R0CS
Top Assembly Part Number : 800-31324-03
Top Assembly Revision Number : B0
Version ID : V03
CLEI Code Number : COMJZ00ARC
Hardware Board Revision Number : 0x04
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
Configuration register is 0xF
###show post
Stored system POST messages:
Switch 1
---------
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: MA BIST : Begin
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: SF ASIC BIST : Begin
POST: SF ASIC BIST : End, Status Passed
POST: Switch Fabric Memory Tests : Begin
POST: Switch Fabric Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: PortASIC Macsec Loopback Tests : Begin
POST: PortASIC Macsec Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 26 message lines logged
Log Buffer (4096 bytes):
*Mar 1 00:00:05.133: Read env variable - LICENSE_BOOT_LEVEL =
*Mar 1 00:00:05.930: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
*Mar 1 00:00:58.015: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
*Mar 1 00:01:00.658: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Mar 1 00:01:00.658: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:01:05.263: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
*Mar 1 00:01:06.152: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
*Mar 1 00:01:06.152: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
*Mar 1 00:01:08.786: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
*Mar 1 00:01:27.392: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
*Mar 1 00:01:27.392: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
*Mar 1 00:01:27.392: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
*Mar 1 00:01:28.692: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
*Mar 1 00:01:29.909: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2012 by Cisco Systems, Inc.
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
*Mar 1 00:01:29.976: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:29.976: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Mar 1 00:01:31.486: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
*Mar 1 00:01:31.888: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
*Mar 1 00:01:32.895: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
*Mar 1 00:01:38.943: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
*Mar 1 00:01:39.958: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
*Mar 1 01:31:38.094: %SYS-2-NULLCHUNK: Memory requested from Null Chunk -Process= "Exec", ipl= 0, pid= 108
-Traceback= 4F0C38z 1BDD608z 20B3708z 20B4A38z CA4008z CBEB68z 443DD4z 449FF4z 45963Cz 262D580z 2627CD0z###show env all
FAN 1 is OK
FAN 2 is OK
FAN PS-1 is OK
FAN PS-2 is NOT PRESENT
SYSTEM TEMPERATURE is OK
System Temperature Value: 30 Degree Celsius
System Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 60 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
--- ------------------ ---------- --------------- ------- ------- -----
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
1B Not Present
SW Status RPS Name RPS Serial# RPS Port#
-- ------------- ---------------- ----------- ---------
1 Not Present <>
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
FastEthernet0 unassigned YES unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/0/25 unassigned YES unset down down
GigabitEthernet1/0/26 unassigned YES unset down down
GigabitEthernet1/0/27 unassigned YES unset down down
GigabitEthernet1/0/28 unassigned YES unset down down
GigabitEthernet1/0/29 unassigned YES unset down down
GigabitEthernet1/0/30 unassigned YES unset down down
GigabitEthernet1/0/31 unassigned YES unset down down
GigabitEthernet1/0/32 unassigned YES unset down down
GigabitEthernet1/0/33 unassigned YES unset down down
GigabitEthernet1/0/34 unassigned YES unset down down
GigabitEthernet1/0/35 unassigned YES unset down down
GigabitEthernet1/0/36 unassigned YES unset down down
GigabitEthernet1/0/37 unassigned YES unset down down
GigabitEthernet1/0/38 unassigned YES unset down down
GigabitEthernet1/0/39 unassigned YES unset down down
GigabitEthernet1/0/40 unassigned YES unset down down
GigabitEthernet1/0/41 unassigned YES unset down down
GigabitEthernet1/0/42 unassigned YES unset down down
GigabitEthernet1/0/43 unassigned YES unset down down
GigabitEthernet1/0/44 unassigned YES unset down down
GigabitEthernet1/0/45 unassigned YES unset down down
GigabitEthernet1/0/46 unassigned YES unset down down
GigabitEthernet1/0/47 unassigned YES unset down down
GigabitEthernet1/0/48 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-48
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#
*Mar 1 01:54:53.506: %SYS-5-CONFIG_I: Configured from console by consoleconfigure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
Router uptime is 13 minutes
System returned to ROM by reload at 02:37:08 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL174510ZN
3 Gigabit Ethernet interfaces
1 terminal line
1 Virtual Private Network (VPN) Module
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL174510ZN
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security securityk9 Permanent securityk9
uc uck9 Permanent uck9
data None None None
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:13:16 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC17428K3K
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : C1
Deviation Number : 130603
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL174510ZN
Chassis MAC Address : 78da.6e42.4a48
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : ART1904F3KX
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan Rotation Alert: Total 2 Fan Low RPM
Fan 1 OK, Maximum speed setting
Fan 2 OK, Maximum speed setting
Fan 3 OK, Maximum speed setting
Fan 4 Low RPM
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 18 Celsius, Normal
Intake Left temperature: 21 Celsius, Normal
Exhaust Right(Bezel) temperature: 23 Celsius, Normal
Exhaust Right temperature: 21 Celsius, Normal
CPU temperature: 41 Celsius, Normal
Power Supply Unit temperature: 21 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 82.8 W
Total System Power consumption is: 82.8 W
Environmental information last updated 00:00:16 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 37 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 37 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 40 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.935: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:05.091: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = securityk9 and License = securityk9
*Jan 2 00:00:05.247: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.587: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
*Jul 21 02:53:35.635: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 02:53:42.063: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 02:53:53.515: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Initialized
*Jul 21 02:53:53.519: %VPN_HW-6-INFO_LOC: Crypto engine: onboard 0 State changed to: Enabled
*Jul 21 02:53:54.403: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:53:54.403: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:53:55.535: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:53:56.355: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 02:54:12.851: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 02:54:13.883: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 02:54:13.883: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:54:14.507: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 02:54:14.547: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 02:54:15.159: %SYS-6-BOOTTIME: Time taken to reboot after reload = 1027 seconds
*Jul 21 02:54:15.787: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Jul 21 02:54:15.787: %CRYPTO-6-GDOI_ON_OFF: GDOI is OFF
*Jul 21 02:55:20.191: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 02:55:21.963: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
*Jul 21 02:55:22.007: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 02:55:22.047: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 02:55:25.779: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:55:26.779: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 02:59:16.315: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
*Jul 21 03:04:46.863: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset up up
GigabitEthernet0/1 unassigned YES unset down down
GigabitEthernet0/2 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 8 minutes
System returned to ROM by Reload command
System image file is "flash:packages.conf"
Last reload reason: Reload command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
% No connections to Shell Manager available for processing the command
###show logging
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 46 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 47 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 48 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
PKI/SSL unable to send Sudi support to WCM
*Jul 21 03:24:53.205: %HMANRP-6-HMAN_IOS_CHANNEL_INFO: HMAN-IOS channel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 03:24:53.915: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 03:24:53.925: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 03:24:53.925: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 03:24:53.925: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 03:24:37.887: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 03:24:37.888: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 03:24:37.888: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 03:24:37.888: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:24:37.888: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:24:37.888: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:24:37.888: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 03:24:55.917: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 03:24:55.974: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 03:24:55.974: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 03:24:57.193: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 03:24:57.678: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 03:24:58.999: %SYS-6-BOOTTIME: Time taken to reboot after reload = 7277 seconds
*Jul 21 03:24:59.092: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 03:24:59.100: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 03:24:59.100: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 03:24:59.100: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 03:24:59.100: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 03:24:59.101: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 03:24:59.101: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 03:24:59.101: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 03:24:59.657: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 03:25:00.092: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 03:25:00.108: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 03:25:00.108: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 03:25:00.109: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 03:25:00.109: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 03:25:00.109: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 03:25:00.110: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 03:25:00.110: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 03:25:03.281: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 38 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#
*Jul 21 03:25:45.703: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 03:25:46.283: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
*Jul 21 03:25:46.823: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 03:25:47.413: %SYS-5-CONFIG_I: Configured from console by consoleinterface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=1
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=964805871
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689910069
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
flashfs[7]: 0 files, 1 directories
flashfs[7]: 0 orphaned files, 0 orphaned directories
flashfs[7]: Total bytes: 6784000
flashfs[7]: Bytes used: 1024
flashfs[7]: Bytes available: 6782976
flashfs[7]: flashfs fsck took 1 seconds....done Initializing Flash.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 44 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 46 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
PKI/SSL unable to send Sudi support to WCM
*Jul 21 03:40:44.491: %HMANRP-6-HMAN_IOS_CHANNEL_INFO: HMAN-IOS channel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 03:40:27.579: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 03:40:27.579: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 03:40:27.579: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 03:40:27.579: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:40:27.579: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:40:27.579: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 03:40:27.579: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 03:40:45.143: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 03:40:45.143: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 03:40:45.144: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 03:40:45.145: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 03:40:46.735: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 03:40:47.406: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 03:40:48.406: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 03:40:48.740: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 03:40:49.311: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 03:40:50.638: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 03:40:50.639: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 03:40:50.642: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 03:40:50.643: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 03:40:50.645: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 03:40:50.648: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 03:40:50.654: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 03:40:50.654: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 03:40:50.778: %SYS-6-BOOTTIME: Time taken to reboot after reload = 781 seconds
*Jul 21 03:40:51.305: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 03:40:51.638: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 03:40:51.640: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 03:40:51.643: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 03:40:51.644: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 03:40:51.647: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 03:40:51.648: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 03:40:51.653: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 03:40:51.654: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 03:40:54.847: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 36 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#
*Jul 21 03:41:56.216: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 03:41:56.828: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=2
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1335259466
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689911177
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
% No connections to Shell Manager available for processing the command
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 46 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
PKI/SSL unable to send Sudi support to WCM
*Jul 21 04:08:02.465: %HMANRP-6-HMAN_IOS_CHANNEL_INFO: HMAN-IOS channel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 04:07:48.322: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 04:07:48.322: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 04:07:48.323: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 04:07:48.323: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 04:08:03.098: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 04:08:03.107: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 04:08:03.107: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 04:08:03.108: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 04:08:04.754: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 04:08:05.452: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 04:08:06.351: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 04:08:06.780: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 04:08:07.495: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 04:08:08.610: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:08.611: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:08.614: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:08.625: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:08.625: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:08.626: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:08.627: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:08.628: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:08.836: %SYS-6-BOOTTIME: Time taken to reboot after reload = 1311 seconds
*Jul 21 04:08:09.489: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 04:08:09.611: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:09.612: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:09.615: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:09.625: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:09.626: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:09.627: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:09.628: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:09.628: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:13.384: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 36 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
*Jul 21 04:08:56.908: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:57.396: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:57.905: %SYS-5-CONFIG_I: Configured from console by consoleinterface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#
*Jul 21 04:08:58.394: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:59.375: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 3 minutes
Uptime for this control processor is 6 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 53 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 53 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 54 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
as been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 04:07:48.323: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 04:08:03.098: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 04:08:03.107: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 04:08:03.107: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 04:08:03.108: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 04:08:04.754: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 04:08:05.452: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 04:08:06.351: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 04:08:06.780: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 04:08:07.495: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 04:08:08.610: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:08.611: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:08.614: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:08.625: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:08.625: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:08.626: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:08.627: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:08.628: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:08.836: %SYS-6-BOOTTIME: Time taken to reboot after reload = 1311 seconds
*Jul 21 04:08:09.489: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 04:08:09.611: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:09.612: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:09.615: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:09.625: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:09.626: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 04:08:09.627: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 04:08:09.628: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 04:08:09.628: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 04:08:13.384: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
*Jul 21 04:08:55.658: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:56.227: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:56.908: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:57.396: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:57.905: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:58.394: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:59.375: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:08:59.983: %SYS-5-CONFIG_I: Configured from console by console###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 35 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#
*Jul 21 04:11:08.330: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 04:11:08.933: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=123516319
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689919061
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
flashfs[7]: 0 files, 1 directories
flashfs[7]: 0 orphaned files, 0 orphaned directories
flashfs[7]: Total bytes: 6784000
flashfs[7]: Bytes used: 1024
flashfs[7]: Bytes available: 6782976
flashfs[7]: flashfs fsck took 1 seconds....done Initializing Flash.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================ERROR=============================================================
Load IOS failed+
=======================================
****NO CONNECTION TO TFTP SERVER****
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch:
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=123516319
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689919061
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch: format flash:
Are you sure you want to format "flash:" (all data will be lost) (y/n)?y
Filesystem "flash:" not formatted -- invalid argument
switch: set DEFAULT_ROUTER 172.16.5.2
switch: set IP_ADDR 172.16.19.108/255.255.0.0
switch: ping 192.168.5.7
ping 192.168.5.7 with 32 bytes of data ...
Up 1000 Mbps Full duplex (port 0) (SGMII)
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=123516319
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689919061
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
% No connections to Shell Manager available for processing the command
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 46 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
PKI/SSL unable to send Sudi support to WCM
*Jul 21 06:11:19.097: %HMANRP-6-HMAN_IOS_CHANNEL_INFO: HMAN-IOS channel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 06:11:03.233: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 06:11:03.234: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 06:11:03.234: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 06:11:03.234: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 06:11:19.643: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 06:11:19.644: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 06:11:19.647: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:11:19.647: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:11:21.704: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:11:22.369: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:11:22.429: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:11:23.847: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:11:24.386: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:11:25.747: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:25.748: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:25.749: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:25.754: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:25.755: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:25.758: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:25.759: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:25.760: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:25.876: %SYS-6-BOOTTIME: Time taken to reboot after reload = 824 seconds
*Jul 21 06:11:26.373: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:11:26.756: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:26.758: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:26.758: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:26.759: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:26.761: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:29.957: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 22 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 36 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#
*Jul 21 06:12:13.541: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:14.101: %SYS-5-CONFIG_I: Configured from console by consoleconfigure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#
*Jul 21 06:12:14.632: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:15.269: %SYS-5-CONFIG_I: Configured from console by consoleend
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 3 minutes
Uptime for this control processor is 6 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 53 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 53 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 54 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
as been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:11:03.234: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 06:11:19.643: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 06:11:19.644: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 06:11:19.647: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:11:19.647: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:11:21.704: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:11:22.369: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:11:22.429: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:11:23.847: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:11:24.386: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:11:25.747: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:25.748: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:25.749: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:25.754: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:25.755: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:25.758: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:25.759: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:25.760: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:25.876: %SYS-6-BOOTTIME: Time taken to reboot after reload = 824 seconds
*Jul 21 06:11:26.373: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:11:26.756: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:26.757: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:26.758: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:11:26.758: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:11:26.759: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:11:26.761: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:11:29.957: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
*Jul 21 06:12:13.541: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:14.101: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:14.632: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:15.269: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:15.750: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:16.385: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:16.865: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:12:17.356: %SYS-5-CONFIG_I: Configured from console by console###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 22 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 34 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
*Jul 21 06:14:24.387: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:14:24.948: %SYS-5-CONFIG_I: Configured from console by consoleinterface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
*Jul 21 06:14:26.592: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:14:27.207: %SYS-5-CONFIG_I: Configured from console by consoleconfigure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
iscoasa###show inv
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
ciscoasa###show version
Cisco Adaptive Security Appliance Software Version 9.5(1)
Compiled on Wed 12-Aug-15 12:18 PDT by builders
System image file is "disk0:/asa951-lfbff-k8.SPA"
Config file at boot was "startup-config"
ciscoasa up 3 mins 33 secs
Hardware: ASA5516, 8192 MB RAM, CPU Atom C2000 series 2416 MHz, 1 CPU (8 cores)
Internal ATA Compact Flash, 8192MB
BIOS Flash unknown @ 0x0, 0KB
Encryption hardware device : Cisco ASA Crypto on-board accelerator (revision 0x1)
Number of accelerators: 1
1: Ext: GigabitEthernet1/1 : address is ecbd.1d5f.a632, irq 255
2: Ext: GigabitEthernet1/2 : address is ecbd.1d5f.a633, irq 255
3: Ext: GigabitEthernet1/3 : address is ecbd.1d5f.a634, irq 255
4: Ext: GigabitEthernet1/4 : address is ecbd.1d5f.a635, irq 255
5: Ext: GigabitEthernet1/5 : address is ecbd.1d5f.a636, irq 255
6: Ext: GigabitEthernet1/6 : address is ecbd.1d5f.a637, irq 255
7: Ext: GigabitEthernet1/7 : address is ecbd.1d5f.a638, irq 255
8: Ext: GigabitEthernet1/8 : address is ecbd.1d5f.a639, irq 255
9: Int: Internal-Data1/1 : address is ecbd.1d5f.a631, irq 255
<--- More --->
10: Int: Internal-Data1/2 : address is 0000.0001.0002, irq 0
11: Int: Internal-Control1/1 : address is 0000.0001.0001, irq 0
12: Int: Internal-Data1/3 : address is 0000.0001.0003, irq 0
13: Ext: Management1/1 : address is ecbd.1d5f.a631, irq 0
The Running Activation Key feature: 500 AnyConnect Premium sessions exceed the limit on the platform, reduced to 300 AnyConnect Premium sessions.
Licensed features for this platform:
Maximum Physical Interfaces : Unlimited perpetual
Maximum VLANs : 150 perpetual
Inside Hosts : Unlimited perpetual
Failover : Active/Active perpetual
Encryption-DES : Enabled perpetual
Encryption-3DES-AES : Enabled perpetual
Security Contexts : 2 perpetual
GTP/GPRS : Disabled perpetual
AnyConnect Premium Peers : 300 perpetual
AnyConnect Essentials : Disabled perpetual
Other VPN Peers : 300 perpetual
Total VPN Peers : 300 perpetual
Shared License : Disabled perpetual
AnyConnect for Mobile : Enabled perpetual
AnyConnect for Cisco VPN Phone : Enabled perpetual
Advanced Endpoint Assessment : Enabled perpetual
Total UC Proxy Sessions : 1000 perpetual
<--- More --->
Botnet Traffic Filter : Disabled perpetual
<--- More --->
Cluster : Disabled perpetual
VPN Load Balancing : Enabled perpetual
Serial Number: JAD193302L9
Running Permanent Activation Key: 0x803fd871 0x648697a2 0x88b2913c 0xbf282ce4 0x8233308c
Configuration register is 0x1
Image type : Release
Key Version : A
Configuration has not been modified since last system restart.
ciscoasa# diag
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show env all
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show log
Syslog logging: disabled
Facility: 20
Timestamp logging: disabled
Hide Username logging: enabled
Standby logging: disabled
Debug-trace logging: disabled
Console logging: disabled
Monitor logging: disabled
Buffer logging: disabled
Trap logging: disabled
Permit-hostdown logging: disabled
History logging: disabled
Device ID: disabled
Mail logging: disabled
ASDM logging: disabled
ciscoasa###show power
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa#
ciscoasa#
ciscoasa#
ciscoasa#
^
ERROR: % Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
GigabitEthernet1/1 unassigned YES unset administratively down down
GigabitEthernet1/2 unassigned YES unset administratively down down
GigabitEthernet1/3 unassigned YES unset administratively down down
GigabitEthernet1/4 unassigned YES unset administratively down down
GigabitEthernet1/5 unassigned YES unset administratively down down
GigabitEthernet1/6 unassigned YES unset administratively down down
GigabitEthernet1/7 unassigned YES unset administratively down down
GigabitEthernet1/8 unassigned YES unset administratively down down
Internal-Control1/1 127.0.1.1 YES unset up up
Internal-Data1/1 unassigned YES unset down down
Internal-Data1/2 unassigned YES unset down down
Internal-Data1/3 unassigned YES unset up up
Management1/1 unassigned YES unset administratively down down
configure terminal
ciscoasa(config)# interface GigabitEthernet1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/2
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/3
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/4
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/5
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/6
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/7
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/8
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Control1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/2
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/3
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Management1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa#
Finish
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1294693117
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689920587
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
flashfs[7]: 0 files, 1 directories
flashfs[7]: 0 orphaned files, 0 orphaned directories
flashfs[7]: Total bytes: 6784000
flashfs[7]: Bytes used: 1024
flashfs[7]: Bytes available: 6782976
flashfs[7]: flashfs fsck took 1 seconds....done Initializing Flash.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================ERROR=============================================================
Load IOS failed+
=======================================
****NO CONNECTION TO TFTP SERVER****
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch:
switch: set
ABNORMAL_RESET_COUNT=0
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1294693117
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689920587
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch: format flash:
Are you sure you want to format "flash:" (all data will be lost) (y/n)?y
Filesystem "flash:" not formatted -- invalid argument
switch: set DEFAULT_ROUTER 172.16.5.2
switch: set IP_ADDR 172.16.19.108/255.255.0.0
switch: ping 192.168.5.7
ping 192.168.5.7 with 32 bytes of data ...
Up 1000 Mbps Full duplex (port 0) (SGMII)
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 46 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 47 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
nel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 06:36:39.564: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 06:36:39.565: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 06:36:39.566: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 06:36:39.566: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:36:23.500: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 06:36:23.501: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 06:36:23.501: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 06:36:23.501: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:36:23.501: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:36:23.501: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:36:23.501: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 06:36:41.880: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:36:42.925: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:36:42.926: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:36:43.283: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:36:43.897: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:36:44.155: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:36:45.219: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:36:45.221: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:36:45.222: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:36:45.227: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:36:45.227: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:36:45.230: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:36:45.231: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:36:45.234: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:36:45.493: %SYS-6-BOOTTIME: Time taken to reboot after reload = 818 seconds
*Jul 21 06:36:45.888: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:36:46.218: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:36:46.226: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:36:46.226: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:36:46.227: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:36:46.227: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:36:46.231: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:36:46.231: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:36:46.235: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:36:49.579: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 36 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================loadingIOS=============================================================
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch: set
ABNORMAL_RESET_COUNT=1
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1843789011
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689921609
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
flashfs[7]: 0 files, 1 directories
flashfs[7]: 0 orphaned files, 0 orphaned directories
flashfs[7]: Total bytes: 6784000
flashfs[7]: Bytes used: 1024
flashfs[7]: Bytes available: 6782976
flashfs[7]: flashfs fsck took 1 seconds....done Initializing Flash.
switch:
switch: SWITCH_IGNORE_STARTUP_CFG=1
switch: flash:packages.conf: no such file or directory
Cannot open file flash:packages.conf
usage: boot [<filename>] [<cmdline>]
switch:
=============================================================ERROR=============================================================
Load IOS failed+
=======================================
****NO CONNECTION TO TFTP SERVER****
clear line 25
[confirm]
[OK]
AU-dev#connect p8
Trying p8 (1.1.1.1, 2025)... Open
switch:
switch: set
ABNORMAL_RESET_COUNT=1
ASIC_PCI_RESET=1
BAUD=9600
BOOT=flash:packages.conf
BOOT_LOADER_UPGRADE_DISABLE=1
BSI=0
CFG_MODEL_NUM=WS-C3850-24P-S
CLEI_CODE_NUMBER=IPM8A00ARC
CSR_PCIERST_DISCONNECTED=yes
DC_COPY=yes
DEFAULT_ROUTER=172.16.5.2
D_STACK_DOMAIN_NUM=1
ECI_CODE_NUMBER=470023
GOLD_MBIT=0
IP_ADDR=172.16.19.108/255.255.0.0
LICENSE_BOOT_LEVEL=ipbasek9,all:ngwc;
MAC_ADDR=34:F8:E7:3A:2D:00
MANUAL_BOOT=no
MODEL_NUM=WS-C3850-24P
MODEL_REVISION_NUM=AD0
MOTHERBOARD_ASSEMBLY_NUM=73-15805-05
MOTHERBOARD_REVISION_NUM=B0
MOTHERBOARD_SERIAL_NUM=FOC22380CKD
POE1_ASSEMBLY_NUM=73-16439-02
POE1_REVISION_NUM=A0
POE1_SERIAL_NUM=FOC22380T2K
RANDOM_NUM=1843789011
RECOVERY_BUNDLE=sda9:cat3k_caa-recovery.bin
RET_2_RCALTS=1689921609
STKPWR_ASSEMBLY_NUM=73-11956-08
STKPWR_REVISION_NUM=B0
STKPWR_SERIAL_NUM=FOC22378NNV
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=1
SYSTEM_SERIAL_NUM=FCW2239F0FC
TAN_NUM=800-43046-03
TAN_REVISION_NUMBER=D0
TEMPLATE=advanced
TERMLINES=0
USB_ASSEMBLY_NUM=73-16576-01
USB_REVISION_NUM=A0
USB_SERIAL_NUM=FOC22376D2N
VERSION_ID=V08
switch:
switch: flash_init
Initializing Flash...
...The flash is already initialized.
switch: format flash:
Are you sure you want to format "flash:" (all data will be lost) (y/n)?y
Filesystem "flash:" not formatted -- invalid argument
switch: set DEFAULT_ROUTER 172.16.5.2
switch: set IP_ADDR 172.16.19.108/255.255.0.0
switch: ping 192.168.5.7
ping 192.168.5.7 with 32 bytes of data ...
Up 1000 Mbps Full duplex (port 0) (SGMII)
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================loadingIOS=============================================================
clear line 22
[confirm]
[OK]
AU-dev#connect p5
Trying p5 (1.1.1.1, 2022)... Open
rommon 1 > show info
monitor: command "show" not found
rommon 2 > set
PS1=rommon ! >
RTC_STAT=0
TFTP_RETRY_COUNT=20
WARM_REBOOT=FALSE
LICENSE_BOOT_LEVEL=datak9,datak9:c2900;
DEFAULT_GATEWAY=172.16.5.2
IP_ADDRESS=172.16.19.105
IP_SUBNET_MASK=255.255.0.0
TFTP_SERVER=192.168.5.7
TFTP_FILE=i/c2900-universalk9-mz.SPA.152-4.M4.bin
?=0
RELOAD_TYPE=1
BSI=0
RANDOM_NUM=1950297411
RET_2_RTS=06:45:30 UTC Fri Jul 21 2023
RET_2_RCALTS=1689921930
rommon 3 > showmon
Last Reset Reason: System Reset
ReadOnly ROMMON version is:
System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 2011 by cisco Systems, Inc.
No upgrade ROMMON version present
ReadOnly ROMMON currently running
ReadOnly ROMMON is selected for next boot
rommon 4 > confreg
Configuration Summary
(Virtual Configuration Register: 0x2142)
enabled are:
load rom after netboot fails
ignore system config info
console baud: 9600
boot: image specified by the boot system commands
or default to: cisco2-CISCO2911/K9
do you wish to change the configuration? y/n [n]: n
rommon 5 >
rommon 5 >
rommon 5 > confreg 0x2142
rommon 6 > reset
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 minute
Uptime for this control processor is 4 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
% No connections to Shell Manager available for processing the command
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 45 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 46 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
PKI/SSL unable to send Sudi support to WCM
*Jul 21 06:51:51.452: %HMANRP-6-HMAN_IOS_CHANNEL_INFO: HMAN-IOS channel event for switch 1: EMP_RELAY: Channel UP!
*Jul 21 06:51:35.217: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 1 on Switch 1 is nocable
*Jul 21 06:51:35.217: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is down
*Jul 21 06:51:35.217: %STACKMGR-6-STACK_LINK_CHANGE: Switch 1 R0/0: stack_mgr: Stack port 2 on Switch 1 is nocable
*Jul 21 06:51:35.217: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:51:35.217: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:51:35.217: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:51:35.217: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 06:51:51.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 06:51:51.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 06:51:51.994: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:51:51.994: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:51:54.524: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:51:54.611: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:51:54.612: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:51:56.140: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:51:56.791: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:51:57.985: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:57.995: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.998: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.001: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.193: %SYS-6-BOOTTIME: Time taken to reboot after reload = 709 seconds
*Jul 21 06:51:58.786: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:51:58.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.996: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.997: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.998: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:59.001: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:52:02.703: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 35 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
*Jul 21 06:52:50.922: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:51.533: %SYS-5-CONFIG_I: Configured from console by consoleinterface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================Wait=============================================================
Device has been broken waiting for testing
=============================================================DPELP=============================================================
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
RAM: 0.46G
Flash: 0.24G
=================================================================
Router####show inv
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
###show ver
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
Router uptime is 1 minute
System returned to ROM by reload at 06:45:30 UTC Fri Jul 21 2023
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
Last reload type: Normal Reload
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
Processor board ID FGL1648103D
3 Gigabit Ethernet interfaces
1 terminal line
DRAM configuration is 64 bits wide with parity enabled.
255K bytes of non-volatile configuration memory.
250880K bytes of ATA System CompactFlash 0 (Read/Write)
License Info:
License UDI:
-------------------------------------------------
Device# PID SN
-------------------------------------------------
*0 CISCO2911/K9 FGL1648103D
Technology Package License Information for Module:'c2900'
-----------------------------------------------------------------
Technology Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbase ipbasek9 Permanent ipbasek9
security None None None
uc uck9 Permanent uck9
data datak9 RightToUse datak9
Configuration register is 0x2142
###show diag
Slot 0:
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time 00:01:10 ago
EEPROM contents at hardware discovery:
PCB Serial Number : FOC164480UZ
Hardware Revision : 1.0
Part Number : 73-11833-11
Top Assy. Part Number : 800-30797-06
Board Revision : A0
Deviation Number : 0
Fab Version : 03
Product (FRU) Number : CISCO2911/K9
Version Identifier : V07
CLEI Code : CMMJD00ARA
Processor type : C1
Chassis Serial Number : FGL1648103D
Chassis MAC Address : e02f.6d31.8080
MAC Address block size : 80
Manufacturing Test Data : 00 00 00 00 00 00 00 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Internal Power Supply information
Top Assy. Part Number : 341-0236-04
Deviation Number : 0
PCB Serial Number : AZS173900LM
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
Version Identifier : V02
Product (FRU) Number : PWR-2911-POE
CLEI Code : COUPAFRBAB
Board Revision : A0
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Embedded Service Engine 0/0 :
Total platform memory : 524288K bytes
Total 2nd core memory : 0K bytes
Start of physical address for 2nd core : 0x80000000
Virtual address start of 2nd core memory : 0x0 - 0x0
2nd core configured disabled
L2 cache ways for 2nd core : 0
###show post
^
% Invalid input detected at '^' marker.
###show env all
SYSTEM POWER SUPPLY STATUS
==========================
Internal Power Supply Type: AC-POE
Internal Power Supply 12V Output Status: Normal
Internal Power Supply POE -48V Voltage Status: Normal
External Redundant Power Supply is absent or powered off
SYSTEM FAN STATUS
=================
Fan 1 OK, Low speed setting
Fan 2 OK, Low speed setting
Fan 3 OK, Low speed setting
Fan 4 OK, Low speed setting
SYSTEM TEMPERATURE STATUS
=========================
Intake Left(Bezel) temperature: 20 Celsius, Normal
Intake Left temperature: 23 Celsius, Normal
Exhaust Right(Bezel) temperature: 25 Celsius, Normal
Exhaust Right temperature: 26 Celsius, Normal
CPU temperature: 48 Celsius, Normal
Power Supply Unit temperature: 26 Celsius, Normal
REAL TIME CLOCK BATTERY STATUS
==============================
Battery OK (checked at power up)
SYSTEM POWER
===============
Motherboard Components Power consumption = 48.7 W
Total System Power consumption is: 48.7 W
Environmental information last updated 00:00:17 ago
###show logging
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 22 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 25 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (8192 bytes):
*Jan 2 00:00:04.743: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
*Jan 2 00:00:04.919: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
*Jan 2 00:00:05.079: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
*Jul 21 07:00:48.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
*Jul 21 07:00:55.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
*Jul 21 07:01:06.431: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
*Jul 21 07:01:08.375: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
*Jul 21 07:01:18.711: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
*Jul 21 07:01:18.711: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
*Jul 21 07:01:21.139: %SYS-5-RESTART: System restarted --
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2013 by Cisco Systems, Inc.
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
*Jul 21 07:01:21.179: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
*Jul 21 07:01:21.791: %SYS-6-BOOTTIME: Time taken to reboot after reload = 952 seconds###show power
^
% Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
GigabitEthernet0/0 unassigned YES unset administratively down down
GigabitEthernet0/1 unassigned YES unset administratively down down
GigabitEthernet0/2 unassigned YES unset administratively down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#interface range GigabitEthernet0/0-2
Router(config-if-range)#no shut
Router(config-if-range)#end
Router#
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 hour, 38 minutes
Uptime for this control processor is 1 hour, 42 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 54 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 54 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 55 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
k_mgr: Switch 1 has been added to the stack.
*Jul 21 06:51:35.217: %STACKMGR-6-SWITCH_ADDED: Switch 1 R0/0: stack_mgr: Switch 1 has been added to the stack.
*Jul 21 06:51:35.217: %STACKMGR-6-ACTIVE_ELECTED: Switch 1 R0/0: stack_mgr: Switch 1 has been elected ACTIVE.
*Jul 21 06:51:51.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface Lsmpi18/3, changed state to up
*Jul 21 06:51:51.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface EOBC18/1, changed state to up
*Jul 21 06:51:51.994: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:51:51.994: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:51:54.524: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:51:54.611: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:51:54.612: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:51:56.140: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:51:56.791: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:51:57.985: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:57.995: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.998: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.001: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.193: %SYS-6-BOOTTIME: Time taken to reboot after reload = 709 seconds
*Jul 21 06:51:58.786: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:51:58.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.996: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.997: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.998: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:59.001: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:52:02.703: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
*Jul 21 06:52:48.698: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:49.259: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:49.790: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:50.281: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:50.922: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:51.533: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:52.032: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:52.653: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:56:10.388: %PLATFORM_FEP-1-FRU_PS_ACCESS: Switch 1: power supply A is not responding###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 33 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#
*Jul 21 08:30:10.190: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:10.751: %SYS-5-CONFIG_I: Configured from console by consoleend
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#
*Jul 21 08:30:11.282: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:11.834: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#
*Jul 21 08:30:12.364: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:12.998: %SYS-5-CONFIG_I: Configured from console by consoleinterface Te1/1/4
Switch(config-if)#no shut
Switch(config-if)#end
Switch#
=============================================================DPELP=============================================================
iscoasa###show inv
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
ciscoasa###show version
Cisco Adaptive Security Appliance Software Version 9.5(1)
Compiled on Wed 12-Aug-15 12:18 PDT by builders
System image file is "disk0:/asa951-lfbff-k8.SPA"
Config file at boot was "startup-config"
ciscoasa up 2 hours 10 mins
Hardware: ASA5516, 8192 MB RAM, CPU Atom C2000 series 2416 MHz, 1 CPU (8 cores)
Internal ATA Compact Flash, 8192MB
BIOS Flash unknown @ 0x0, 0KB
Encryption hardware device : Cisco ASA Crypto on-board accelerator (revision 0x1)
Number of accelerators: 1
1: Ext: GigabitEthernet1/1 : address is ecbd.1d5f.a632, irq 255
2: Ext: GigabitEthernet1/2 : address is ecbd.1d5f.a633, irq 255
3: Ext: GigabitEthernet1/3 : address is ecbd.1d5f.a634, irq 255
4: Ext: GigabitEthernet1/4 : address is ecbd.1d5f.a635, irq 255
5: Ext: GigabitEthernet1/5 : address is ecbd.1d5f.a636, irq 255
6: Ext: GigabitEthernet1/6 : address is ecbd.1d5f.a637, irq 255
7: Ext: GigabitEthernet1/7 : address is ecbd.1d5f.a638, irq 255
8: Ext: GigabitEthernet1/8 : address is ecbd.1d5f.a639, irq 255
9: Int: Internal-Data1/1 : address is ecbd.1d5f.a631, irq 255
<--- More --->
10: Int: Internal-Data1/2 : address is 0000.0001.0002, irq 0
11: Int: Internal-Control1/1 : address is 0000.0001.0001, irq 0
12: Int: Internal-Data1/3 : address is 0000.0001.0003, irq 0
13: Ext: Management1/1 : address is ecbd.1d5f.a631, irq 0
The Running Activation Key feature: 500 AnyConnect Premium sessions exceed the limit on the platform, reduced to 300 AnyConnect Premium sessions.
Licensed features for this platform:
Maximum Physical Interfaces : Unlimited perpetual
Maximum VLANs : 150 perpetual
Inside Hosts : Unlimited perpetual
Failover : Active/Active perpetual
Encryption-DES : Enabled perpetual
Encryption-3DES-AES : Enabled perpetual
Security Contexts : 2 perpetual
GTP/GPRS : Disabled perpetual
AnyConnect Premium Peers : 300 perpetual
AnyConnect Essentials : Disabled perpetual
Other VPN Peers : 300 perpetual
Total VPN Peers : 300 perpetual
Shared License : Disabled perpetual
AnyConnect for Mobile : Enabled perpetual
AnyConnect for Cisco VPN Phone : Enabled perpetual
Advanced Endpoint Assessment : Enabled perpetual
Total UC Proxy Sessions : 1000 perpetual
<--- More --->
Botnet Traffic Filter : Disabled perpetual
<--- More --->
Cluster : Disabled perpetual
VPN Load Balancing : Enabled perpetual
Serial Number: JAD193302L9
Running Permanent Activation Key: 0x803fd871 0x648697a2 0x88b2913c 0xbf282ce4 0x8233308c
Configuration register is 0x1
Image type : Release
Key Version : A
Configuration last modified by enable_15 at 07:35:54.989 UTC Fri Jul 21 2023
ciscoasa# diag
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show env all
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa###show log
Syslog logging: disabled
Facility: 20
Timestamp logging: disabled
Hide Username logging: enabled
Standby logging: disabled
Debug-trace logging: disabled
Console logging: disabled
Monitor logging: disabled
Buffer logging: disabled
Trap logging: disabled
Permit-hostdown logging: disabled
History logging: disabled
Device ID: disabled
Mail logging: disabled
ASDM logging: disabled
ciscoasa###show power
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa#
ciscoasa#
ciscoasa#
ciscoasa#
^
ERROR: % Invalid input detected at '^' marker.
Interface IP-Address OK? Method Status Protocol
GigabitEthernet1/1 unassigned YES unset down down
GigabitEthernet1/2 unassigned YES unset down down
GigabitEthernet1/3 unassigned YES unset down down
GigabitEthernet1/4 unassigned YES unset down down
GigabitEthernet1/5 unassigned YES unset down down
GigabitEthernet1/6 unassigned YES unset down down
GigabitEthernet1/7 unassigned YES unset down down
GigabitEthernet1/8 unassigned YES unset down down
Internal-Control1/1 127.0.1.1 YES unset up up
Internal-Data1/1 unassigned YES unset up down
Internal-Data1/2 unassigned YES unset down down
Internal-Data1/3 unassigned YES unset up up
Management1/1 unassigned YES unset down down
configure terminal
ciscoasa(config)# interface GigabitEthernet1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/2
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/3
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/4
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/5
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/6
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/7
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface GigabitEthernet1/8
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Control1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/1
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/2
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Internal-Data1/3
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config)# no shut
^
ERROR: % Invalid input detected at '^' marker.
ciscoasa(config
ciscoasa(config)# end
ciscoasa# configure terminal
ciscoasa(config)# interface Management1/1
ciscoasa(config-if)# no shut
ciscoasa(config-if)# end
ciscoasa#
Finish
=============================================================DPEL=============================================================
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
RAM: 0.81G
Flash: 1.53G
=================================================================
Switch####show inv
NAME: "c38xx Stack", DESCR: "c38xx Stack"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
###show ver
Cisco IOS XE Software, Version 16.06.05
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: IOS-XE ROMMON
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
Switch uptime is 1 hour, 51 minutes
Uptime for this control processor is 1 hour, 55 minutes
System returned to ROM by Reload Command
System image file is "flash:packages.conf"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
-----------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------
ipbasek9 Permanent ipbasek9
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
Processor board ID FCW2239F0FC
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
4 Ten Gigabit Ethernet interfaces
2048K bytes of non-volatile configuration memory.
4194304K bytes of physical memory.
250456K bytes of Crash Files at crashinfo:.
1609272K bytes of Flash at flash:.
0K bytes of WebUI ODM Files at webui:.
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
Motherboard Assembly Number : 73-15805-05
Motherboard Serial Number : FOC22380CKD
Model Revision Number : AD0
Motherboard Revision Number : B0
Model Number : WS-C3850-24P
System Serial Number : FCW2239F0FC
Switch Ports Model SW Version SW Image Mode
------ ----- ----- ---------- ---------- ----
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
Configuration register is 0x142 (will be 0x102 at next reload)
###show post
Stored system POST messages:
Switch 1
---------
POST: MBIST Tests : Begin
POST: MBIST Tests : End, Status Passed
POST: CRYPTO Tests : Begin
POST: CRYPTO Tests : End, Status Passed
POST: PHY Loopback: loopback Test : Begin
POST: PHY Loopback: loopback Test : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Temperature Tests : Begin
POST: Thermal, Temperature Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: SIF Tests : Begin
POST: SIF Tests : End, Status Passed
###show logging
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
No Inactive Message Discriminator.
Console logging: level debugging, 62 messages logged, xml disabled,
filtering disabled
Monitor logging: level debugging, 0 messages logged, xml disabled,
filtering disabled
Buffer logging: level debugging, 62 messages logged, xml disabled,
filtering disabled
Exception Logging: size (4096 bytes)
Count and timestamp logging messages: disabled
File logging: disabled
Persistent logging: disabled
No active filter modules.
Trap logging: level informational, 63 message lines logged
Logging Source-Interface: VRF Name:
Log Buffer (4096 bytes):
06:51:51.994: %LINEPROTO-5-UPDOWN: Line protocol on Interface LIIN18/2, changed state to up
*Jul 21 06:51:54.524: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Jul 21 06:51:54.611: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
*Jul 21 06:51:54.612: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
*Jul 21 06:51:56.140: %IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-vrf created with ID 1, ipv4 table-id 0x1, ipv6 table-id 0x1E000001
*Jul 21 06:51:56.791: %SYS-5-RESTART: System restarted --
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2018 by Cisco Systems, Inc.
Compiled Mon 10-Dec-18 11:34 by mcpre
*Jul 21 06:51:57.985: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:57.995: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:57.998: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.001: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.193: %SYS-6-BOOTTIME: Time taken to reboot after reload = 709 seconds
*Jul 21 06:51:58.786: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
*Jul 21 06:51:58.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:58.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
*Jul 21 06:51:58.996: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
*Jul 21 06:51:58.997: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
*Jul 21 06:51:58.998: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
*Jul 21 06:51:59.001: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
*Jul 21 06:52:02.703: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
*Jul 21 06:52:48.698: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:49.259: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:49.790: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:50.281: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:50.922: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:51.533: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:52.032: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:52:52.653: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 06:56:10.388: %PLATFORM_FEP-1-FRU_PS_ACCESS: Switch 1: power supply A is not responding
*Jul 21 08:30:10.190: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:10.751: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:11.282: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:11.834: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:12.364: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:12.998: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:13.478: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:30:14.060: %SYS-5-CONFIG_I: Configured from console by console###show env all
Switch 1 FAN 1 is OK
Switch 1 FAN 2 is OK
Switch 1 FAN 3 is OK
FAN PS-1 is NOT PRESENT
FAN PS-2 is OK
Switch 1: SYSTEM TEMPERATURE is OK
Inlet Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius
Red Threshold : 56 Degree Celsius
Hotspot Temperature Value: 33 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 105 Degree Celsius
Red Threshold : 125 Degree Celsius
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A Unknown Unknown No Input Power Bad Bad 235
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
Any interface listed with OK? value "NO" does not have a valid configuration
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES unset up down
GigabitEthernet0/0 unassigned NO unset up up
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset down down
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/1/1 unassigned YES unset down down
GigabitEthernet1/1/2 unassigned YES unset down down
GigabitEthernet1/1/3 unassigned YES unset down down
GigabitEthernet1/1/4 unassigned YES unset down down
Te1/1/1 unassigned YES unset down down
Te1/1/2 unassigned YES unset down down
Te1/1/3 unassigned YES unset down down
Te1/1/4 unassigned YES unset down down ^
% Invalid input detected at '^' marker.
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface GigabitEthernet0/0
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/0/1-24
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface range GigabitEthernet1/1/1-4
Switch(config-if-range)#no shut
Switch(config-if-range)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Vlan1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/1
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/2
Switch(config-if)#no shut
Switch(config-if)#
*Jul 21 08:43:11.349: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:43:11.829: %SYS-5-CONFIG_I: Configured from console by consoleend
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/3
Switch(config-if)#no shut
Switch(config-if)#end
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface Te1/1/4
Switch(config-if)#
*Jul 21 08:43:12.452: %SYS-5-CONFIG_I: Configured from console by console
*Jul 21 08:43:13.003: %SYS-5-CONFIG_I: Configured from console by consoleno shut
Switch(config-if)#end
Switch#