1927 lines
86 KiB
Plaintext
1927 lines
86 KiB
Plaintext
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL1648103D, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL1648103D
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: AZS173900LM
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 16 hours, 44 minutes
|
||
System returned to ROM by reload at 06:45:30 UTC Fri Jul 21 2023
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL1648103D
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL1648103D
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security None None None
|
||
uc uck9 Permanent uck9
|
||
data datak9 RightToUse datak9
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 16:44:40 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC164480UZ
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : A0
|
||
Deviation Number : 0
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL1648103D
|
||
Chassis MAC Address : e02f.6d31.8080
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 36 34 34 38 30 55 5A 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 41 30 88 00 00 00 00 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 36 34 38 31 30 33 44
|
||
0x60: C3 06 E0 2F 6D 31 80 80 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : AZS173900LM
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 5A 53 31 37 33 39 30 30 4C 4D 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan 1 OK, Low speed setting
|
||
Fan 2 OK, Low speed setting
|
||
Fan 3 OK, Low speed setting
|
||
Fan 4 OK, Low speed setting
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 18 Celsius, Normal
|
||
Intake Left temperature: 22 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 24 Celsius, Normal
|
||
Exhaust Right temperature: 25 Celsius, Normal
|
||
CPU temperature: 47 Celsius, Normal
|
||
Power Supply Unit temperature: 25 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 50.6 W
|
||
Total System Power consumption is: 50.6 W
|
||
|
||
Environmental information last updated 00:00:23 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 28 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 28 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 31 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
|
||
*Jan 2 00:00:04.743: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
||
*Jan 2 00:00:04.919: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = uck9 and License = uck9
|
||
*Jan 2 00:00:05.079: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
||
*Jul 21 07:00:48.639: c3600_scp_set_dstaddr2_idb(184)add = 80 name is Embedded-Service-Engine0/0
|
||
*Jul 21 07:00:55.055: %PVDM-6-UNSUPPORTED: Codec G.723 is not supported on PVDM3.
|
||
*Jul 21 07:01:06.431: %LINEPROTO-5-UPDOWN: Line protocol on Interface VoIP-Null0, changed state to up
|
||
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 21 07:01:06.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 21 07:01:07.619: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 21 07:01:08.375: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
|
||
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
|
||
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
|
||
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
|
||
*Jul 21 07:01:17.667: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
|
||
*Jul 21 07:01:18.711: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
|
||
*Jul 21 07:01:18.711: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 21 07:01:21.139: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
*Jul 21 07:01:21.179: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|
||
*Jul 21 07:01:21.791: %SYS-6-BOOTTIME: Time taken to reboot after reload = 952 seconds
|
||
*Jul 21 07:02:17.991: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 07:02:19.759: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
||
*Jul 21 07:02:19.803: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
||
*Jul 21 07:02:19.843: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
||
*Jul 21 07:02:23.431: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to up
|
||
*Jul 21 07:02:24.431: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to up###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset up up
|
||
GigabitEthernet0/1 unassigned YES unset down down
|
||
GigabitEthernet0/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
=============================================================DPEL=============================================================
|
||
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
|
||
RAM: 0.81G
|
||
Flash: 1.53G
|
||
=================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "c38xx Stack", DESCR: "c38xx Stack"
|
||
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
|
||
|
||
NAME: "Switch 1", DESCR: "WS-C3850-24P-S"
|
||
PID: WS-C3850-24P-S , VID: V08 , SN: FCW2239F0FC
|
||
|
||
NAME: "Switch 1 - Power Supply B", DESCR: "Switch 1 - Power Supply B"
|
||
PID: PWR-C1-1100WAC , VID: V01 , SN: LIT20300WP2
|
||
|
||
###show ver
|
||
Cisco IOS XE Software, Version 16.06.05
|
||
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2018 by Cisco Systems, Inc.
|
||
Compiled Mon 10-Dec-18 11:34 by mcpre
|
||
|
||
|
||
Cisco IOS-XE software, Copyright (c) 2005-2018 by cisco Systems, Inc.
|
||
All rights reserved. Certain components of Cisco IOS-XE software are
|
||
licensed under the GNU General Public License ("GPL") Version 2.0. The
|
||
software code licensed under GPL Version 2.0 is free software that comes
|
||
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
|
||
GPL code under the terms of GPL Version 2.0. For more details, see the
|
||
documentation or "License Notice" file accompanying the IOS-XE software,
|
||
or the applicable URL provided on the flyer accompanying the IOS-XE
|
||
software.
|
||
|
||
|
||
ROM: IOS-XE ROMMON
|
||
BOOTLDR: CAT3K_CAA Boot Loader (CAT3K_CAA-HBOOT-M) Version 3.58, RELEASE SOFTWARE (P)
|
||
|
||
Switch uptime is 16 hours, 49 minutes
|
||
Uptime for this control processor is 16 hours, 52 minutes
|
||
System returned to ROM by Reload Command
|
||
System image file is "flash:packages.conf"
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
|
||
Technology Package License Information:
|
||
|
||
-----------------------------------------------------------------
|
||
Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbasek9 Permanent ipbasek9
|
||
|
||
cisco WS-C3850-24P (MIPS) processor (revision AD0) with 853097K/6147K bytes of memory.
|
||
Processor board ID FCW2239F0FC
|
||
1 Virtual Ethernet interface
|
||
28 Gigabit Ethernet interfaces
|
||
4 Ten Gigabit Ethernet interfaces
|
||
2048K bytes of non-volatile configuration memory.
|
||
4194304K bytes of physical memory.
|
||
250456K bytes of Crash Files at crashinfo:.
|
||
1609272K bytes of Flash at flash:.
|
||
0K bytes of WebUI ODM Files at webui:.
|
||
|
||
Base Ethernet MAC Address : 34:f8:e7:3a:2d:00
|
||
Motherboard Assembly Number : 73-15805-05
|
||
Motherboard Serial Number : FOC22380CKD
|
||
Model Revision Number : AD0
|
||
Motherboard Revision Number : B0
|
||
Model Number : WS-C3850-24P
|
||
System Serial Number : FCW2239F0FC
|
||
|
||
|
||
Switch Ports Model SW Version SW Image Mode
|
||
------ ----- ----- ---------- ---------- ----
|
||
* 1 32 WS-C3850-24P 16.6.5 CAT3K_CAA-UNIVERSALK9 INSTALL
|
||
|
||
|
||
Configuration register is 0x142 (will be 0x102 at next reload)
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: MBIST Tests : Begin
|
||
POST: MBIST Tests : End, Status Passed
|
||
|
||
POST: CRYPTO Tests : Begin
|
||
POST: CRYPTO Tests : End, Status Passed
|
||
|
||
POST: PHY Loopback: loopback Test : Begin
|
||
POST: PHY Loopback: loopback Test : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Temperature Tests : Begin
|
||
POST: Thermal, Temperature Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: SIF Tests : Begin
|
||
POST: SIF Tests : End, Status Passed
|
||
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 1 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 70 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 70 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 71 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (4096 bytes):
|
||
-RESTART: System restarted --
|
||
Cisco IOS Software [Everest], Catalyst L3 Switch Software (CAT3K_CAA-UNIVERSALK9-M), Version 16.6.5, RELEASE SOFTWARE (fc3)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2018 by Cisco Systems, Inc.
|
||
Compiled Mon 10-Dec-18 11:34 by mcpre
|
||
*Jul 21 06:51:57.985: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/1, changed state to down
|
||
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/2, changed state to down
|
||
*Jul 21 06:51:57.989: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/3, changed state to down
|
||
*Jul 21 06:51:57.995: %LINK-3-UPDOWN: Interface GigabitEthernet1/1/4, changed state to down
|
||
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/1, changed state to down
|
||
*Jul 21 06:51:57.996: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/2, changed state to down
|
||
*Jul 21 06:51:57.998: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/3, changed state to down
|
||
*Jul 21 06:51:58.001: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/1/4, changed state to down
|
||
*Jul 21 06:51:58.193: %SYS-6-BOOTTIME: Time taken to reboot after reload = 709 seconds
|
||
*Jul 21 06:51:58.786: %LINK-3-UPDOWN: Interface Vlan1, changed state to up
|
||
*Jul 21 06:51:58.985: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/1, changed state to down
|
||
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/2, changed state to down
|
||
*Jul 21 06:51:58.989: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/3, changed state to down
|
||
*Jul 21 06:51:58.993: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1/4, changed state to down
|
||
*Jul 21 06:51:58.996: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/1, changed state to down
|
||
*Jul 21 06:51:58.997: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/2, changed state to down
|
||
*Jul 21 06:51:58.998: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/3, changed state to down
|
||
*Jul 21 06:51:59.001: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/1/4, changed state to down
|
||
*Jul 21 06:52:02.703: %PNP-6-PNP_DISCOVERY_STOPPED: PnP Discovery stopped (Startup Config Present)
|
||
*Jul 21 06:52:48.698: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:49.259: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:49.790: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:50.281: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:50.922: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:51.533: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:52.032: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:52:52.653: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 06:56:10.388: %PLATFORM_FEP-1-FRU_PS_ACCESS: Switch 1: power supply A is not responding
|
||
*Jul 21 08:30:10.190: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:10.751: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:11.282: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:11.834: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:12.364: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:12.998: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:13.478: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:30:14.060: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:10.258: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:10.809: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:11.349: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:11.829: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:12.452: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:13.003: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:13.535: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 08:43:14.151: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
||
Switch 1 FAN 1 is OK
|
||
Switch 1 FAN 2 is OK
|
||
Switch 1 FAN 3 is OK
|
||
FAN PS-1 is NOT PRESENT
|
||
FAN PS-2 is OK
|
||
Switch 1: SYSTEM TEMPERATURE is OK
|
||
Inlet Temperature Value: 21 Degree Celsius
|
||
|
||
Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 56 Degree Celsius
|
||
|
||
Hotspot Temperature Value: 32 Degree Celsius
|
||
Temperature State: GREEN
|
||
Yellow Threshold : 105 Degree Celsius
|
||
Red Threshold : 125 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
-- ------------------ ---------- --------------- ------- ------- -----
|
||
1A Unknown Unknown No Input Power Bad Bad 235
|
||
1B PWR-C1-1100WAC LIT20300WP2 OK Good Good 1100
|
||
Any interface listed with OK? value "NO" does not have a valid configuration
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
GigabitEthernet0/0 unassigned NO unset up up
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down
|
||
Te1/1/3 unassigned YES unset down down
|
||
Te1/1/4 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface GigabitEthernet0/0
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-24
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#
|
||
*Jul 21 23:41:06.844: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 23:41:07.395: %SYS-5-CONFIG_I: Configured from console by consoleend
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/3
|
||
Switch(config-if)#
|
||
*Jul 21 23:41:07.925: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Jul 21 23:41:08.410: %SYS-5-CONFIG_I: Configured from console by consoleno shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/4
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
|
||
RAM: 0.46G
|
||
Flash: 0.24G
|
||
=================================================================
|
||
|
||
Router####show inv
|
||
NAME: "CISCO2911/K9", DESCR: "CISCO2911/K9 chassis, Hw Serial#: FGL174510ZN, Hw Revision: 1.0"
|
||
PID: CISCO2911/K9 , VID: V07 , SN: FGL174510ZN
|
||
|
||
NAME: "C2911 AC-POE Power Supply", DESCR: "C2911 AC-POE Power Supply"
|
||
PID: PWR-2911-POE , VID: V02 , SN: ART1904F3KX
|
||
|
||
###show ver
|
||
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.2(4)M4, RELEASE SOFTWARE (fc2)
|
||
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2013 by Cisco Systems, Inc.
|
||
Compiled Thu 20-Jun-13 13:06 by prod_rel_team
|
||
|
||
ROM: System Bootstrap, Version 15.0(1r)M16, RELEASE SOFTWARE (fc1)
|
||
|
||
Router uptime is 21 hours, 7 minutes
|
||
System returned to ROM by reload at 02:37:08 UTC Fri Jul 21 2023
|
||
System image file is "flash0:c2900-universalk9-mz.SPA.152-4.M4.bin"
|
||
Last reload type: Normal Reload
|
||
Last reload reason: Reload Command
|
||
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
||
Processor board ID FGL174510ZN
|
||
3 Gigabit Ethernet interfaces
|
||
1 terminal line
|
||
1 Virtual Private Network (VPN) Module
|
||
DRAM configuration is 64 bits wide with parity enabled.
|
||
255K bytes of non-volatile configuration memory.
|
||
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
||
|
||
|
||
License Info:
|
||
|
||
License UDI:
|
||
|
||
-------------------------------------------------
|
||
Device# PID SN
|
||
-------------------------------------------------
|
||
*0 CISCO2911/K9 FGL174510ZN
|
||
|
||
|
||
|
||
Technology Package License Information for Module:'c2900'
|
||
|
||
-----------------------------------------------------------------
|
||
Technology Technology-package Technology-package
|
||
Current Type Next reboot
|
||
------------------------------------------------------------------
|
||
ipbase ipbasek9 Permanent ipbasek9
|
||
security securityk9 Permanent securityk9
|
||
uc uck9 Permanent uck9
|
||
data None None None
|
||
|
||
Configuration register is 0x2142
|
||
###show diag
|
||
Slot 0:
|
||
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
||
Port adapter is analyzed
|
||
Port adapter insertion time 21:06:54 ago
|
||
EEPROM contents at hardware discovery:
|
||
PCB Serial Number : FOC17428K3K
|
||
Hardware Revision : 1.0
|
||
Part Number : 73-11833-11
|
||
Top Assy. Part Number : 800-30797-06
|
||
Board Revision : C1
|
||
Deviation Number : 130603
|
||
Fab Version : 03
|
||
Product (FRU) Number : CISCO2911/K9
|
||
|
||
Version Identifier : V07
|
||
CLEI Code : CMMJD00ARA
|
||
Processor type : C1
|
||
Chassis Serial Number : FGL174510ZN
|
||
Chassis MAC Address : 78da.6e42.4a48
|
||
MAC Address block size : 80
|
||
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF C1 8B 46 4F 43 31 37 34 32 38 4B 33 4B 40
|
||
0x10: 06 18 41 01 00 82 49 2E 39 0B C0 46 03 20 00 78
|
||
0x20: 4D 06 42 43 31 88 00 01 FE 2B 02 03 CB 8C 43 49
|
||
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 37 20 D9
|
||
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 4A 44 30 30 41 52
|
||
0x50: 41 09 C1 C2 8B 46 47 4C 31 37 34 35 31 30 5A 4E
|
||
0x60: C3 06 78 DA 6E 42 4A 48 43 00 50 C4 08 00 00 00
|
||
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
||
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
Internal Power Supply information
|
||
Top Assy. Part Number : 341-0236-04
|
||
Deviation Number : 0
|
||
PCB Serial Number : ART1904F3KX
|
||
RMA Test History : 00
|
||
RMA Number : 0-0-0-0
|
||
RMA History : 00
|
||
Version Identifier : V02
|
||
Product (FRU) Number : PWR-2911-POE
|
||
CLEI Code : COUPAFRBAB
|
||
Board Revision : A0
|
||
EEPROM format version 4
|
||
EEPROM contents (hex):
|
||
0x00: 04 FF 40 05 E6 DF 45 01 55 00 EC 04 88 00 00 00
|
||
0x10: 00 C1 8B 41 52 54 31 39 30 34 46 33 4B 58 03 00
|
||
0x20: 81 00 00 00 00 04 00 89 56 30 32 20 CB 8C 50 57
|
||
0x30: 52 2D 32 39 31 31 2D 50 4F 45 C6 8A 43 4F 55 50
|
||
0x40: 41 46 52 42 41 42 F3 00 59 41 01 86 42 00 05 F8
|
||
0x50: 00 50 02 12 17 BA 03 15 19 94 04 17 1B 24 05 19
|
||
0x60: 1C 51 06 1A 1D 1F 07 1B 1D F2 08 1C 1E 9F 09 1C
|
||
0x70: 1F 26 0A 1D 1F 94 0B 1C 1F ED 0C 1C 20 36 0E 1A
|
||
0x80: 20 A9 10 16 20 F9 12 11 21 31 14 0B 21 5D 17 FA
|
||
0x90: 21 8A 1B E4 21 9B 1F C9 21 98 23 A8 21 87 27 82
|
||
0xA0: 21 B1 42 41 30 FF FF FF FF FF FF FF FF FF FF FF
|
||
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
||
|
||
|
||
Embedded Service Engine 0/0 :
|
||
Total platform memory : 524288K bytes
|
||
Total 2nd core memory : 0K bytes
|
||
Start of physical address for 2nd core : 0x80000000
|
||
Virtual address start of 2nd core memory : 0x0 - 0x0
|
||
2nd core configured disabled
|
||
L2 cache ways for 2nd core : 0
|
||
###show post
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
###show env all
|
||
SYSTEM POWER SUPPLY STATUS
|
||
==========================
|
||
Internal Power Supply Type: AC-POE
|
||
Internal Power Supply 12V Output Status: Normal
|
||
Internal Power Supply POE -48V Voltage Status: Normal
|
||
|
||
External Redundant Power Supply is absent or powered off
|
||
|
||
SYSTEM FAN STATUS
|
||
=================
|
||
Fan Rotation Alert: Total 2 Fan Low RPM
|
||
Fan 1 OK, Maximum speed setting
|
||
Fan 2 OK, Maximum speed setting
|
||
Fan 3 OK, Maximum speed setting
|
||
Fan 4 Low RPM
|
||
|
||
SYSTEM TEMPERATURE STATUS
|
||
=========================
|
||
Intake Left(Bezel) temperature: 20 Celsius, Normal
|
||
Intake Left temperature: 22 Celsius, Normal
|
||
Exhaust Right(Bezel) temperature: 25 Celsius, Normal
|
||
Exhaust Right temperature: 22 Celsius, Normal
|
||
CPU temperature: 43 Celsius, Normal
|
||
Power Supply Unit temperature: 22 Celsius, Normal
|
||
|
||
REAL TIME CLOCK BATTERY STATUS
|
||
==============================
|
||
Battery OK (checked at power up)
|
||
|
||
SYSTEM POWER
|
||
===============
|
||
Motherboard Components Power consumption = 82.7 W
|
||
Total System Power consumption is: 82.7 W
|
||
|
||
Environmental information last updated 00:00:09 ago
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 4 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 266 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 266 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 269 message lines logged
|
||
Logging Source-Interface: VRF Name:
|
||
|
||
Log Buffer (8192 bytes):
|
||
igh for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 19:42:03.851: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 19:47:34.419: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 19:53:05.039: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 19:58:35.607: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:04:06.227: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:09:36.795: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:15:07.415: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:20:37.983: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:26:08.603: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:31:39.171: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:37:09.791: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:42:40.359: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:48:10.979: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:53:41.547: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 20:59:12.167: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:04:42.743: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:10:13.355: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:15:43.923: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:21:14.543: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:26:45.111: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:32:15.731: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:37:46.299: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:43:16.919: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:48:47.487: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:54:18.107: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 21:59:48.675: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:05:19.295: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:10:49.863: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:16:20.483: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:21:51.051: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:27:21.671: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:32:52.239: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:38:22.859: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:43:53.427: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:49:24.047: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 22:54:54.615: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:00:25.235: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:05:55.802: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:11:26.422: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:16:56.990: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:22:27.610: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:27:58.178: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:33:28.798: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:38:59.366: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:44:29.986: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:50:00.554: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.
|
||
*Jul 21 23:55:31.174: %ENVMON-4-ONE_FAN_LOW_RPM: Warning: Fan 4 is running at low RPM. Rotation speed is now high for all other fans. Fan Tray replacement is recommended.###show power
|
||
^
|
||
% Invalid input detected at '^' marker.
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Embedded-Service-Engine0/0 unassigned YES unset administratively down down
|
||
GigabitEthernet0/0 unassigned YES unset up up
|
||
GigabitEthernet0/1 unassigned YES unset down down
|
||
GigabitEthernet0/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Router(config)#interface range GigabitEthernet0/0-2
|
||
Router(config-if-range)#no shut
|
||
Router(config-if-range)#end
|
||
Router#
|
||
|
||
|
||
|
||
=============================================================Faulty=============================================================
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
RAM: 0.25G
|
||
Flash: 0.00G
|
||
=================================================================
|
||
Faulty:
|
||
-traceback= 4f0c38z 1bdd608z 20b3708z 20b4a38z ca4008z cbeb68z 443dd4z 449ff4z 45963cz 262d580z 2627cd0z
|
||
|
||
======================================================================
|
||
|
||
Switch####show inv
|
||
NAME: "1", DESCR: "WS-C3750X-48P"
|
||
PID: WS-C3750X-48PF-S , VID: V03 , SN: FDO1628R0CS
|
||
|
||
|
||
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"
|
||
PID: C3KX-PWR-350WAC , VID: V02L , SN: LIT164117TZ
|
||
|
||
###show ver
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
|
||
ROM: Bootstrap program is C3750E boot loader
|
||
BOOTLDR: C3750E Boot Loader (C3750X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
||
|
||
Switch uptime is 22 hours, 57 minutes
|
||
System returned to ROM by power-on
|
||
System image file is "flash:/c3750e-ipbasek9-mz.150-2.SE.bin"
|
||
|
||
|
||
This product contains cryptographic features and is subject to United
|
||
States and local country laws governing import, export, transfer and
|
||
use. Delivery of Cisco cryptographic products does not imply
|
||
third-party authority to import, export, distribute or use encryption.
|
||
Importers, exporters, distributors and users are responsible for
|
||
compliance with U.S. and local country laws. By using this product you
|
||
agree to comply with applicable laws and regulations. If you are unable
|
||
to comply with U.S. and local laws, return this product immediately.
|
||
|
||
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
||
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
||
|
||
If you require further assistance please contact us by sending email to
|
||
export@cisco.com.
|
||
|
||
|
||
License Level: ipbase
|
||
License Type: Permanent
|
||
Next reload license Level: ipbase
|
||
|
||
cisco WS-C3750X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
||
Processor board ID FDO1628R0CS
|
||
Last reset from power-on
|
||
1 Virtual Ethernet interface
|
||
1 FastEthernet interface
|
||
52 Gigabit Ethernet interfaces
|
||
2 Ten Gigabit Ethernet interfaces
|
||
The password-recovery mechanism is enabled.
|
||
|
||
512K bytes of flash-simulated non-volatile configuration memory.
|
||
Base ethernet MAC Address : 30:F7:0D:88:A0:00
|
||
Motherboard assembly number : 73-12553-06
|
||
Motherboard serial number : FDO1628033U
|
||
Model revision number : A0
|
||
Motherboard revision number : A0
|
||
Model number : WS-C3750X-48PF-S
|
||
Daughterboard assembly number : 800-32727-03
|
||
Daughterboard serial number : FDO16271VNS
|
||
System serial number : FDO1628R0CS
|
||
Top Assembly Part Number : 800-31324-03
|
||
Top Assembly Revision Number : B0
|
||
Version ID : V03
|
||
CLEI Code Number : COMJZ00ARC
|
||
Hardware Board Revision Number : 0x04
|
||
|
||
|
||
Switch Ports Model SW Version SW Image
|
||
------ ----- ----- ---------- ----------
|
||
* 1 54 WS-C3750X-48P 15.0(2)SE C3750E-IPBASEK9-M
|
||
|
||
|
||
Configuration register is 0xF
|
||
###show post
|
||
Stored system POST messages:
|
||
|
||
Switch 1
|
||
---------
|
||
|
||
POST: CPU MIC register Tests : Begin
|
||
POST: CPU MIC register Tests : End, Status Passed
|
||
|
||
POST: MA BIST : Begin
|
||
POST: MA BIST : End, Status Passed
|
||
|
||
POST: TCAM BIST : Begin
|
||
POST: TCAM BIST : End, Status Passed
|
||
|
||
POST: SF ASIC BIST : Begin
|
||
POST: SF ASIC BIST : End, Status Passed
|
||
|
||
POST: Switch Fabric Memory Tests : Begin
|
||
POST: Switch Fabric Memory Tests : End, Status Passed
|
||
|
||
POST: CPU MIC interface Loopback Tests : Begin
|
||
|
||
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC RingLoopback Tests : Begin
|
||
POST: PortASIC RingLoopback Tests : End, Status Passed
|
||
|
||
POST: Inline Power Controller Tests : Begin
|
||
POST: Inline Power Controller Tests : End, Status Passed
|
||
|
||
POST: Thermal, Fan Tests : Begin
|
||
POST: Thermal, Fan Tests : End, Status Passed
|
||
|
||
POST: PortASIC Port Loopback Tests : Begin
|
||
POST: PortASIC Port Loopback Tests : End, Status Passed
|
||
|
||
POST: PortASIC Macsec Loopback Tests : Begin
|
||
POST: PortASIC Macsec Loopback Tests : End, Status Passed
|
||
|
||
POST: EMAC Loopback Tests : Begin
|
||
POST: EMAC Loopback Tests : End, Status Passed
|
||
###show logging
|
||
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
||
|
||
No Active Message Discriminator.
|
||
|
||
|
||
|
||
No Inactive Message Discriminator.
|
||
|
||
|
||
Console logging: level debugging, 27 messages logged, xml disabled,
|
||
filtering disabled
|
||
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
||
filtering disabled
|
||
Buffer logging: level debugging, 27 messages logged, xml disabled,
|
||
filtering disabled
|
||
Exception Logging: size (4096 bytes)
|
||
Count and timestamp logging messages: disabled
|
||
File logging: disabled
|
||
Persistent logging: disabled
|
||
|
||
No active filter modules.
|
||
|
||
Trap logging: level informational, 31 message lines logged
|
||
|
||
Log Buffer (4096 bytes):
|
||
|
||
*Mar 1 00:00:05.133: Read env variable - LICENSE_BOOT_LEVEL =
|
||
*Mar 1 00:00:05.930: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3750x Next reboot level = ipbase and License = ipbase
|
||
*Mar 1 00:00:58.015: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack
|
||
*Mar 1 00:01:00.658: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
||
*Mar 1 00:01:00.658: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:05.263: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
||
*Mar 1 00:01:06.152: %DC-4-FILE_OPEN_WARNING: Not able to open flash:/dc_profile_dir/dc_default_profiles.txt
|
||
*Mar 1 00:01:06.152: %DC-6-DEFAULT_INIT_INFO: Default Profiles DB not loaded.
|
||
*Mar 1 00:01:08.786: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 inserted
|
||
*Mar 1 00:01:27.392: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
|
||
*Mar 1 00:01:27.392: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:27.392: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
|
||
*Mar 1 00:01:28.692: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
|
||
*Mar 1 00:01:29.909: %SYS-5-RESTART: System restarted --
|
||
Cisco IOS Software, C3750E Software (C3750E-IPBASEK9-M), Version 15.0(2)SE, RELEASE SOFTWARE (fc1)
|
||
Technical Support: http://www.cisco.com/techsupport
|
||
Copyright (c) 1986-2012 by Cisco Systems, Inc.
|
||
Compiled Fri 27-Jul-12 23:25 by prod_rel_team
|
||
*Mar 1 00:01:29.976: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:29.976: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
|
||
*Mar 1 00:01:31.486: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
||
*Mar 1 00:01:31.888: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:32.895: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
||
*Mar 1 00:01:38.943: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
||
*Mar 1 00:01:39.958: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
||
*Mar 1 01:31:38.094: %SYS-2-NULLCHUNK: Memory requested from Null Chunk -Process= "Exec", ipl= 0, pid= 108
|
||
-Traceback= 4F0C38z 1BDD608z 20B3708z 20B4A38z CA4008z CBEB68z 443DD4z 449FF4z 45963Cz 262D580z 2627CD0z
|
||
*Mar 1 01:54:53.506: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 01:54:55.200: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 01:54:56.165: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 01:55:07.448: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 01:55:08.991: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
||
FAN 1 is OK
|
||
FAN 2 is OK
|
||
FAN PS-1 is OK
|
||
FAN PS-2 is NOT PRESENT
|
||
SYSTEM TEMPERATURE is OK
|
||
System Temperature Value: 28 Degree Celsius
|
||
System Temperature State: GREEN
|
||
Yellow Threshold : 46 Degree Celsius
|
||
Red Threshold : 60 Degree Celsius
|
||
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
||
--- ------------------ ---------- --------------- ------- ------- -----
|
||
1A C3KX-PWR-350WAC LIT164117TZ OK Good Good 350/0
|
||
1B Not Present
|
||
|
||
SW Status RPS Name RPS Serial# RPS Port#
|
||
-- ------------- ---------------- ----------- ---------
|
||
1 Not Present <>
|
||
|
||
Interface IP-Address OK? Method Status Protocol
|
||
Vlan1 unassigned YES unset up down
|
||
FastEthernet0 unassigned YES unset up up
|
||
GigabitEthernet1/0/1 unassigned YES unset down down
|
||
GigabitEthernet1/0/2 unassigned YES unset down down
|
||
GigabitEthernet1/0/3 unassigned YES unset down down
|
||
GigabitEthernet1/0/4 unassigned YES unset down down
|
||
GigabitEthernet1/0/5 unassigned YES unset down down
|
||
GigabitEthernet1/0/6 unassigned YES unset down down
|
||
GigabitEthernet1/0/7 unassigned YES unset down down
|
||
GigabitEthernet1/0/8 unassigned YES unset down down
|
||
GigabitEthernet1/0/9 unassigned YES unset down down
|
||
GigabitEthernet1/0/10 unassigned YES unset down down
|
||
GigabitEthernet1/0/11 unassigned YES unset down down
|
||
GigabitEthernet1/0/12 unassigned YES unset down down
|
||
GigabitEthernet1/0/13 unassigned YES unset down down
|
||
GigabitEthernet1/0/14 unassigned YES unset down down
|
||
GigabitEthernet1/0/15 unassigned YES unset down down
|
||
|
||
GigabitEthernet1/0/16 unassigned YES unset down down
|
||
GigabitEthernet1/0/17 unassigned YES unset down down
|
||
GigabitEthernet1/0/18 unassigned YES unset down down
|
||
GigabitEthernet1/0/19 unassigned YES unset down down
|
||
GigabitEthernet1/0/20 unassigned YES unset down down
|
||
GigabitEthernet1/0/21 unassigned YES unset down down
|
||
GigabitEthernet1/0/22 unassigned YES unset down down
|
||
GigabitEthernet1/0/23 unassigned YES unset down down
|
||
GigabitEthernet1/0/24 unassigned YES unset down down
|
||
GigabitEthernet1/0/25 unassigned YES unset down down
|
||
GigabitEthernet1/0/26 unassigned YES unset down down
|
||
GigabitEthernet1/0/27 unassigned YES unset down down
|
||
GigabitEthernet1/0/28 unassigned YES unset down down
|
||
GigabitEthernet1/0/29 unassigned YES unset down down
|
||
GigabitEthernet1/0/30 unassigned YES unset down down
|
||
GigabitEthernet1/0/31 unassigned YES unset down down
|
||
GigabitEthernet1/0/32 unassigned YES unset down down
|
||
GigabitEthernet1/0/33 unassigned YES unset down down
|
||
GigabitEthernet1/0/34 unassigned YES unset down down
|
||
GigabitEthernet1/0/35 unassigned YES unset down down
|
||
GigabitEthernet1/0/36 unassigned YES unset down down
|
||
GigabitEthernet1/0/37 unassigned YES unset down down
|
||
GigabitEthernet1/0/38 unassigned YES unset down down
|
||
GigabitEthernet1/0/39 unassigned YES unset down down
|
||
GigabitEthernet1/0/40 unassigned YES unset down down
|
||
GigabitEthernet1/0/41 unassigned YES unset down down
|
||
GigabitEthernet1/0/42 unassigned YES unset down down
|
||
GigabitEthernet1/0/43 unassigned YES unset down down
|
||
GigabitEthernet1/0/44 unassigned YES unset down down
|
||
GigabitEthernet1/0/45 unassigned YES unset down down
|
||
GigabitEthernet1/0/46 unassigned YES unset down down
|
||
GigabitEthernet1/0/47 unassigned YES unset down down
|
||
GigabitEthernet1/0/48 unassigned YES unset down down
|
||
GigabitEthernet1/1/1 unassigned YES unset down down
|
||
GigabitEthernet1/1/2 unassigned YES unset down down
|
||
GigabitEthernet1/1/3 unassigned YES unset down down
|
||
GigabitEthernet1/1/4 unassigned YES unset down down
|
||
Te1/1/1 unassigned YES unset down down
|
||
Te1/1/2 unassigned YES unset down down ^
|
||
% Invalid input detected at '^' marker.
|
||
configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface range GigabitEthernet1/0/1-48
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#interface range GigabitEthernet1/1/1-4
|
||
Switch(config-if-range)#no shut
|
||
Switch(config-if-range)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Vlan1
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#interface Te1/1/1
|
||
Switch(config-if)#
|
||
*Mar 1 22:57:37.641: %SYS-5-CONFIG_I: Configured from console by consoleno shut
|
||
Switch(config-if)#end
|
||
Switch#configure terminal
|
||
Enter configuration commands, one per line. End with CNTL/Z.
|
||
Switch(config)#
|
||
*Mar 1 22:57:39.201: %SYS-5-CONFIG_I: Configured from console by console
|
||
*Mar 1 22:57:40.174: %SYS-5-CONFIG_I: Configured from console by consoleinterface Te1/1/2
|
||
Switch(config-if)#no shut
|
||
Switch(config-if)#end
|
||
Switch#
|
||
|
||
|
||
=============================================================DPELP=============================================================
|
||
iscoasa###show inv
|
||
Name: "Chassis", DESCR: "ASA 5516-X with FirePOWER services, 8GE, AC, DES"
|
||
PID: ASA5516 , VID: V06 , SN: JMX1936Z0XM
|
||
|
||
|
||
|