220 lines
8.6 KiB
Plaintext
220 lines
8.6 KiB
Plaintext
###show inv
|
|
NAME: "CISCO2911/K9 chassis", DESCR: "CISCO2911/K9 chassis"
|
|
PID: CISCO2911/K9 , VID: V02 , SN: FGL151412EC
|
|
|
|
NAME: "C2911 AC Power Supply", DESCR: "C2911 AC Power Supply"
|
|
PID: PWR-2911-AC , VID: V03 , SN: AZS151110F0
|
|
|
|
###show ver
|
|
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.0(1)M4, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2010 by Cisco Systems, Inc.
|
|
Compiled Thu 28-Oct-10 18:32 by prod_rel_team
|
|
|
|
ROM: System Bootstrap, Version 15.0(1r)M9, RELEASE SOFTWARE (fc1)
|
|
|
|
Router uptime is 43 minutes
|
|
System returned to ROM by power-on
|
|
System image file is "flash0:c2900-universalk9-mz.SPA.150-1.M4.bin"
|
|
Last reload type: Normal Reload
|
|
|
|
|
|
|
|
This product contains cryptographic features and is subject to United
|
|
States and local country laws governing import, export, transfer and
|
|
use. Delivery of Cisco cryptographic products does not imply
|
|
third-party authority to import, export, distribute or use encryption.
|
|
Importers, exporters, distributors and users are responsible for
|
|
compliance with U.S. and local country laws. By using this product you
|
|
agree to comply with applicable laws and regulations. If you are unable
|
|
to comply with U.S. and local laws, return this product immediately.
|
|
|
|
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
|
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
|
|
|
If you require further assistance please contact us by sending email to
|
|
export@cisco.com.
|
|
|
|
Cisco CISCO2911/K9 (revision 1.0) with 487424K/36864K bytes of memory.
|
|
Processor board ID FGL151412EC
|
|
3 Gigabit Ethernet interfaces
|
|
DRAM configuration is 64 bits wide with parity enabled.
|
|
255K bytes of non-volatile configuration memory.
|
|
250880K bytes of ATA System CompactFlash 0 (Read/Write)
|
|
|
|
|
|
License Info:
|
|
|
|
License UDI:
|
|
|
|
-------------------------------------------------
|
|
Device# PID SN
|
|
-------------------------------------------------
|
|
*0 CISCO2911/K9 FGL151412EC
|
|
|
|
|
|
|
|
Technology Package License Information for Module:'c2900'
|
|
|
|
----------------------------------------------------------------
|
|
Technology Technology-package Technology-package
|
|
Current Type Next reboot
|
|
-----------------------------------------------------------------
|
|
ipbase ipbasek9 Permanent ipbasek9
|
|
security None None None
|
|
uc None None None
|
|
data datak9 Permanent datak9
|
|
|
|
Configuration register is 0x2102
|
|
###show diag
|
|
Slot 0:
|
|
C2911 Mother board 3GE, integrated VPN and 4W Port adapter, 3 ports
|
|
Port adapter is analyzed
|
|
Port adapter insertion time 00:43:07 ago
|
|
EEPROM contents at hardware discovery:
|
|
PCB Serial Number : FOC15115UYG
|
|
Hardware Revision : 1.0
|
|
Part Number : 73-11833-06
|
|
Top Assy. Part Number : 800-30797-02
|
|
Board Revision : B0
|
|
Deviation Number : 113332
|
|
Fab Version : 03
|
|
Product (FRU) Number : CISCO2911/K9
|
|
|
|
Version Identifier : V02
|
|
CLEI Code : CMMBR00ARA
|
|
Processor type : C1
|
|
Chassis Serial Number : FGL151412EC
|
|
Chassis MAC Address : 4055.39ab.b0e0
|
|
MAC Address block size : 80
|
|
Manufacturing Test Data : 00 00 00 00 00 00 00 00
|
|
EEPROM format version 4
|
|
EEPROM contents (hex):
|
|
0x00: 04 FF C1 8B 46 4F 43 31 35 31 31 35 55 59 47 40
|
|
0x10: 06 18 41 01 00 82 49 2E 39 06 C0 46 03 20 00 78
|
|
0x20: 4D 02 42 42 30 88 00 01 BA B4 02 03 CB 8C 43 49
|
|
0x30: 53 43 4F 32 39 31 31 2F 4B 39 89 56 30 32 20 D9
|
|
0x40: 04 40 C1 CB C2 C6 8A 43 4D 4D 42 52 30 30 41 52
|
|
0x50: 41 09 C1 C2 8B 46 47 4C 31 35 31 34 31 32 45 43
|
|
0x60: C3 06 40 55 39 AB B0 E0 43 00 50 C4 08 00 00 00
|
|
0x70: 00 00 00 00 00 F3 00 03 40 01 25 FF FF FF FF FF
|
|
0x80: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0x90: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xA0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
Internal power Supply information
|
|
Top Assy. Part Number : 341-0235-05
|
|
Deviation Number : 0
|
|
PCB Serial Number : AZS151110F0
|
|
RMA Test History : 00
|
|
RMA Number : 0-0-0-0
|
|
RMA History : 00
|
|
Version Identifier : V03
|
|
Product (FRU) Number : PWR-2911-AC
|
|
CLEI Code :
|
|
Board Revision : A0
|
|
EEPROM format version 4
|
|
EEPROM contents (hex):
|
|
0x00: 04 FF 40 05 E5 DF 45 01 55 00 EB 05 88 00 00 00
|
|
0x10: 00 C1 8B 41 5A 53 31 35 31 31 31 30 46 30 03 00
|
|
0x20: 81 00 00 00 00 04 00 89 56 30 33 20 CB 8B 50 57
|
|
0x30: 52 2D 32 39 31 31 2D 41 43 C6 8A 00 00 00 00 00
|
|
0x40: 00 00 00 00 00 F3 00 59 41 00 BE 42 00 05 F8 00
|
|
0x50: 50 01 F4 17 2B 02 EE 1A 7A 03 E8 1B 65 04 E2 1C
|
|
0x60: 47 05 DC 1C C9 06 D6 1D A3 07 D0 1E 54 08 CA 1E
|
|
0x70: E6 09 C4 1F 5C 0A BE 1F BF 0B B8 20 12 0D AC 20
|
|
0x80: 92 0F A0 20 F0 11 94 21 38 13 88 21 6B 17 70 21
|
|
0x90: AE 1B 58 21 D3 1F 40 21 E0 23 28 21 DE 27 10 22
|
|
0xA0: 56 42 41 30 FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xB0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xC0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xD0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xE0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
0xF0: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
|
|
###show post
|
|
^
|
|
% Invalid input detected at '^' marker.
|
|
###show env all
|
|
SYSTEM POWER SUPPLY STATUS
|
|
==========================
|
|
Internal Power Supply Type: AC
|
|
Internal Power Supply 12V Output Status: Normal
|
|
|
|
External Redundant Power Supply is absent or powered off
|
|
|
|
SYSTEM FAN STATUS
|
|
=================
|
|
Fan 1 OK, Low speed setting
|
|
Fan 2 OK, Low speed setting
|
|
Fan 3 OK, Low speed setting
|
|
Fan 4 OK, Low speed setting
|
|
|
|
SYSTEM TEMPERATURE STATUS
|
|
=========================
|
|
Intake Left(Bezel) temperature: 23 Celsius, Normal
|
|
Intake Left temperature: 21 Celsius, Normal
|
|
Exhaust Right(Bezel) temperature: 26 Celsius, Normal
|
|
Exhaust Right temperature: 25 Celsius, Normal
|
|
CPU temperature: 67 Celsius, Normal
|
|
Power Supply Unit temperature: 23 Celsius, Normal
|
|
|
|
REAL TIME CLOCK BATTERY STATUS
|
|
==============================
|
|
Battery OK (checked at power up)
|
|
|
|
SYSTEM POWER
|
|
===============
|
|
Motherboard Components Power consumption = 47.7 W
|
|
Total System Power consumption is: 47.7 W
|
|
|
|
Environmental information last updated 00:00:00 ago
|
|
###show logging
|
|
Syslog logging: enabled (0 messages dropped, 2 messages rate-limited,
|
|
0 flushes, 0 overruns, xml disabled, filtering disabled)
|
|
|
|
No Active Message Discriminator.
|
|
|
|
|
|
|
|
|
|
No Inactive Message Discriminator.
|
|
|
|
|
|
Console logging: level debugging, 11 messages logged, xml disabled,
|
|
filtering disabled
|
|
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
|
filtering disabled
|
|
Buffer logging: level debugging, 11 messages logged, xml disabled,
|
|
filtering disabled
|
|
Logging Exception size (4096 bytes)
|
|
Count and timestamp logging messages: disabled
|
|
Persistent logging: disabled
|
|
|
|
No active filter modules.
|
|
|
|
ESM: 0 messages dropped
|
|
|
|
Trap logging: level informational, 15 message lines logged
|
|
|
|
Log Buffer (8192 bytes):
|
|
|
|
*Mar 1 00:00:09.503: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = ipbasek9 and License = ipbasek9
|
|
*Mar 1 00:00:09.575: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c2900 Next reboot level = datak9 and License = datak9
|
|
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
|
|
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
|
|
*May 18 04:54:21.479: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
|
|
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
|
|
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
|
|
*May 18 04:54:22.683: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
|
|
*May 18 04:54:24.099: %SYS-5-CONFIG_I: Configured from memory by console
|
|
*May 18 04:54:26.571: %SYS-5-RESTART: System restarted --
|
|
Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.0(1)M4, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2010 by Cisco Systems, Inc.
|
|
Compiled Thu 28-Oct-10 18:32 by prod_rel_team
|
|
*May 18 04:54:26.575: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
|