PID: WS-C3560X-48PF-L , VID: V02 , SN: FDO1522V0ZG
|
|
RAM: 0.25G
|
|
Flash: 0.00G
|
|
=================================================================
|
|
Faulty:
|
|
*mar 1 00:01:05.405: %lineproto-5-updown: line protocol on interface fastethernet0, changed state to downauth manager registration failed
|
|
|
|
start interface failed!
|
|
|
|
======================================================================
|
|
|
|
Switch####show inv
|
|
NAME: "1", DESCR: "WS-C3560X-48P"
|
|
PID: WS-C3560X-48PF-L , VID: V02 , SN: FDO1522V0ZG
|
|
|
|
|
|
NAME: "Power Supply 1", DESCR: "FRU Power Supply"
|
|
PID: C3KX-PWR-350WAC , VID: V03D , SN: DCB181790EZ
|
|
|
|
NAME: "FRULink Slot 1 - FRULink Module", DESCR: "FRULink 1G Module"
|
|
PID: C3KX-NM-1G , VID: V01 , SN: FDO15140DCJ
|
|
|
|
###show ver
|
|
Cisco IOS Software, C3560E Software (C3560E-UNIVERSALK9-M), Version 12.2(58)SE2, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2011 by Cisco Systems, Inc.
|
|
Compiled Thu 21-Jul-11 01:34 by prod_rel_team
|
|
|
|
ROM: Bootstrap program is C3560E boot loader
|
|
|
|
BOOTLDR: C3560E Boot Loader (C3560X-HBOOT-M) Version 12.2(53r)SE2, RELEASE SOFTWARE (fc1)
|
|
|
|
Switch uptime is 6 hours, 30 minutes
|
|
System returned to ROM by power-on
|
|
System image file is "flash:/c3560e-universalk9-mz.122-58.SE2.bin"
|
|
|
|
|
|
This product contains cryptographic features and is subject to United
|
|
States and local country laws governing import, export, transfer and
|
|
use. Delivery of Cisco cryptographic products does not imply
|
|
third-party authority to import, export, distribute or use encryption.
|
|
Importers, exporters, distributors and users are responsible for
|
|
compliance with U.S. and local country laws. By using this product you
|
|
agree to comply with applicable laws and regulations. If you are unable
|
|
to comply with U.S. and local laws, return this product immediately.
|
|
|
|
A summary of U.S. laws governing Cisco cryptographic products may be found at:
|
|
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
|
|
|
|
If you require further assistance please contact us by sending email to
|
|
export@cisco.com.
|
|
|
|
License Level: lanbase
|
|
License Type: Permanent
|
|
Next reload license Level: lanbase
|
|
|
|
cisco WS-C3560X-48P (PowerPC405) processor (revision A0) with 262144K bytes of memory.
|
|
Processor board ID FDO1522V0ZG
|
|
Last reset from power-on
|
|
1 Virtual Ethernet interface
|
|
1 FastEthernet interface
|
|
52 Gigabit Ethernet interfaces
|
|
2 Ten Gigabit Ethernet interfaces
|
|
The password-recovery mechanism is enabled.
|
|
|
|
512K bytes of flash-simulated non-volatile configuration memory.
|
|
Base ethernet MAC Address : 00:07:7D:F2:31:80
|
|
Motherboard assembly number : 73-12557-05
|
|
Motherboard serial number : FDO152309K6
|
|
Model revision number : A0
|
|
Motherboard revision number : C0
|
|
Model number : WS-C3560X-48PF-L
|
|
Daughterboard assembly number : 800-32786-01
|
|
Daughterboard serial number : FDO15221S3T
|
|
System serial number : FDO1522V0ZG
|
|
Top Assembly Part Number : 800-31328-02
|
|
Top Assembly Revision Number : C0
|
|
Version ID : V02
|
|
CLEI Code Number : COMJP00ARB
|
|
Hardware Board Revision Number : 0x03
|
|
|
|
|
|
Switch Ports Model SW Version SW Image
|
|
------ ----- ----- ---------- ----------
|
|
* 1 54 WS-C3560X-48P 12.2(58)SE2 C3560E-UNIVERSALK9-M
|
|
|
|
|
|
Configuration register is 0xF
|
|
###show post
|
|
Stored system POST messages:
|
|
|
|
Switch 1
|
|
---------
|
|
|
|
POST: CPU MIC register Tests : Begin
|
|
POST: CPU MIC register Tests : End, Status Passed
|
|
|
|
POST: MA BIST : Begin
|
|
POST: MA BIST : End, Status Passed
|
|
|
|
POST: TCAM BIST : Begin
|
|
POST: TCAM BIST : End, Status Passed
|
|
|
|
POST: SF ASIC BIST : Begin
|
|
POST: SF ASIC BIST : End, Status Passed
|
|
|
|
POST: Switch Fabric Memory Tests : Begin
|
|
POST: Switch Fabric Memory Tests : End, Status Passed
|
|
|
|
POST: CPU MIC interface Loopback Tests : Begin
|
|
|
|
POST: CPU MIC interface Loopback Tests : End, Status Passed
|
|
|
|
POST: PortASIC RingLoopback Tests : Begin
|
|
POST: PortASIC RingLoopback Tests : End, Status Passed
|
|
|
|
POST: Inline Power Controller Tests : Begin
|
|
POST: Inline Power Controller Tests : End, Status Passed
|
|
|
|
POST: Thermal, Fan Tests : Begin
|
|
POST: Thermal, Fan Tests : End, Status Passed
|
|
|
|
POST: PortASIC Port Loopback Tests : Begin
|
|
POST: PortASIC Port Loopback Tests : End, Status Passed
|
|
|
|
POST: EMAC Loopback Tests : Begin
|
|
POST: EMAC Loopback Tests : End, Status Passed
|
|
###show logging
|
|
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
|
|
|
|
No Active Message Discriminator.
|
|
|
|
|
|
|
|
No Inactive Message Discriminator.
|
|
|
|
|
|
Console logging: level debugging, 30 messages logged, xml disabled,
|
|
filtering disabled
|
|
Monitor logging: level debugging, 0 messages logged, xml disabled,
|
|
filtering disabled
|
|
Buffer logging: level debugging, 30 messages logged, xml disabled,
|
|
filtering disabled
|
|
Exception Logging: size (4096 bytes)
|
|
Count and timestamp logging messages: disabled
|
|
File logging: disabled
|
|
Persistent logging: disabled
|
|
|
|
No active filter modules.
|
|
|
|
Trap logging: level informational, 32 message lines logged
|
|
|
|
Log Buffer (4096 bytes):
|
|
|
|
*Mar 1 00:00:04.689: Read env variable - LICENSE_BOOT_LEVEL =
|
|
*Mar 1 00:00:06.861: %IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL: Module name = c3560x Next reboot level = lanbase and License = lanbase
|
|
*Mar 1 00:01:05.405: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
|
|
*Mar 1 00:01:05.405: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to downAuth Manager registration failed
|
|
|
|
*Mar 1 00:01:08.711: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
|
|
*Mar 1 00:01:11.185: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 2 inserted
|
|
*Mar 1 00:01:31.393: %SYS-5-RESTART: System restarted --
|
|
Cisco IOS Software, C3560E Software (C3560E-UNIVERSALK9-M), Version 12.2(58)SE2, RELEASE SOFTWARE (fc1)
|
|
Technical Support: http://www.cisco.com/techsupport
|
|
Copyright (c) 1986-2011 by Cisco Systems, Inc.
|
|
Compiled Thu 21-Jul-11 01:34 by prod_rel_team
|
|
*Mar 1 00:01:32.970: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
|
|
*Mar 1 00:01:32.996: %USB_CONSOLE-6-MEDIA_RJ45: Console media-type is RJ45.
|
|
*Mar 1 00:01:34.841: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to down
|
|
*Mar 1 00:01:38.708: %PLATFORM-6-FRULINK_INSERTED: FRULink 1G module inserted.
|
|
*Mar 1 00:01:40.873: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
|
|
*Mar 1 00:01:41.879: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0, changed state to up
|
|
*Mar 1 00:03:32.256: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:32.777: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:33.280: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:33.968: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:34.521: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:35.192: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:35.830: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:36.342: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:36.887: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:37.415: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:38.070: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:38.791: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:39.303: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:39.974: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:40.477: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 00:03:50.669: %SYS-5-CONFIG_I: Configured from console by console###show env all
|
|
FAN 1 is OK
|
|
FAN 2 is OK
|
|
FAN PS-1 is NOT PRESENT
|
|
FAN PS-2 is OK
|
|
SYSTEM TEMPERATURE is OK
|
|
System Temperature Value: 26 Degree Celsius
|
|
System Temperature State: GREEN
|
|
Yellow Threshold : 46 Degree Celsius
|
|
Red Threshold : 60 Degree Celsius
|
|
SW PID Serial# Status Sys Pwr PoE Pwr Watts
|
|
--- ------------------ ---------- --------------- ------- ------- -----
|
|
1A Not Present
|
|
1B C3KX-PWR-350WAC DCB181790EZ OK Good Good 350/0
|
|
|
|
SW Status RPS Name RPS Serial# RPS Port#
|
|
-- ------------- ---------------- ----------- ---------
|
|
1 Not Present <>
|
|
Interface IP-Address OK? Method Status Protocol
|
|
Vlan1 unassigned YES unset up down
|
|
FastEthernet0 unassigned YES unset up up
|
|
GigabitEthernet0/1 unassigned YES unset down down
|
|
GigabitEthernet0/2 unassigned YES unset down down
|
|
GigabitEthernet0/3 unassigned YES unset down down
|
|
GigabitEthernet0/4 unassigned YES unset down down
|
|
GigabitEthernet0/5 unassigned YES unset down down
|
|
GigabitEthernet0/6 unassigned YES unset down down
|
|
GigabitEthernet0/7 unassigned YES unset down down
|
|
GigabitEthernet0/8 unassigned YES unset down down
|
|
GigabitEthernet0/9 unassigned YES unset down down
|
|
|
|
GigabitEthernet0/10 unassigned YES unset down down
|
|
GigabitEthernet0/11 unassigned YES unset down down
|
|
GigabitEthernet0/12 unassigned YES unset down down
|
|
GigabitEthernet0/13 unassigned YES unset down down
|
|
GigabitEthernet0/14 unassigned YES unset down down
|
|
GigabitEthernet0/15 unassigned YES unset down down
|
|
GigabitEthernet0/16 unassigned YES unset down down
|
|
GigabitEthernet0/17 unassigned YES unset down down
|
|
GigabitEthernet0/18 unassigned YES unset down down
|
|
GigabitEthernet0/19 unassigned YES unset down down
|
|
GigabitEthernet0/20 unassigned YES unset down down
|
|
GigabitEthernet0/21 unassigned YES unset down down
|
|
GigabitEthernet0/22 unassigned YES unset down down
|
|
GigabitEthernet0/23 unassigned YES unset down down
|
|
GigabitEthernet0/24 unassigned YES unset down down
|
|
GigabitEthernet0/25 unassigned YES unset down down
|
|
GigabitEthernet0/26 unassigned YES unset down down
|
|
GigabitEthernet0/27 unassigned YES unset down down
|
|
GigabitEthernet0/28 unassigned YES unset down down
|
|
GigabitEthernet0/29 unassigned YES unset down down
|
|
GigabitEthernet0/30 unassigned YES unset down down
|
|
GigabitEthernet0/31 unassigned YES unset down down
|
|
GigabitEthernet0/32 unassigned YES unset down down
|
|
GigabitEthernet0/33 unassigned YES unset down down
|
|
GigabitEthernet0/34 unassigned YES unset down down
|
|
|
|
GigabitEthernet0/35 unassigned YES unset down down
|
|
GigabitEthernet0/36 unassigned YES unset down down
|
|
GigabitEthernet0/37 unassigned YES unset down down
|
|
GigabitEthernet0/38 unassigned YES unset down down
|
|
GigabitEthernet0/39 unassigned YES unset down down
|
|
GigabitEthernet0/40 unassigned YES unset down down
|
|
GigabitEthernet0/41 unassigned YES unset down down
|
|
GigabitEthernet0/42 unassigned YES unset down down
|
|
GigabitEthernet0/43 unassigned YES unset down down
|
|
GigabitEthernet0/44 unassigned YES unset down down
|
|
GigabitEthernet0/45 unassigned YES unset down down
|
|
GigabitEthernet0/46 unassigned YES unset down down
|
|
GigabitEthernet0/47 unassigned YES unset down down
|
|
GigabitEthernet0/48 unassigned YES unset down down
|
|
GigabitEthernet1/1 unassigned YES unset down down
|
|
GigabitEthernet1/2 unassigned YES unset down down
|
|
GigabitEthernet1/3 unassigned YES unset down down
|
|
GigabitEthernet1/4 unassigned YES unset down down
|
|
TenGigabitEthernet1/1 unassigned YES unset down down
|
|
TenGigabitEthernet1/2 unassigned YES unset down down inter Vlan1
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter FastEthernet0
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/1
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/2
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/3
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/4
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/5
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/6
|
|
Switch(config-if)#
|
|
*Mar 1 06:31:13.765: %SYS-5-CONFIG_I: Configured from console by console
|
|
*Mar 1 06:31:14.277: %SYS-5-CONFIG_I: Configured from console by consoleno shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/7
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/8
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/9
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#inter GigabitEthernet0/10
|
|
Switch(config-if)#no shut
|
|
Switch(config-if)#end
|
|
Switch#
|
|
Start interface failed! |